Table Of ContentÍîìåíêëàòóðíûé êàòàëîã. ×àñòü 4.
ÑÎÄÅÐÆÀÍÈÅ CONTENTS
Îáìîòî÷íûå ïðîâîäà . . . . . . . . . . . . . . . . . . . . . . . . . . . . Winding wires. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
- c ýìàëåâîé èçîëÿöèåé . . . . . . . . . . . . . . . . . . . . . . . . . . . - with enamel insulation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
- ñî ñòåêëîâîëîêíèñòîé èçîëÿöèåé. . . . . . . . . . . . . . . . . . . - with glass-fiber insulation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
- ñ ýìàëåâî-ñòåêëîâîëîêíèñòîé èçîëÿöèåé. . . . . . . . . . . . - with enamel-glass-fiber insulation . . . . . . . . . . . . . . . . . . . . . . . . . 8
- ñ ïëåíî÷íîé èçîëÿöèåé. . . . . . . . . . . . . . . . . . . . . . . . . . . - with film insulation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
- ñ áóìàæíîé èçîëÿöèåé . . . . . . . . . . . . . . . . . . . . . . . . . . . - with paper insulation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Ïðîâîäà äëÿ âûâîäà îáìîòîê. . . . . . . . . . . . . . . . . . . . . Wires for winding outlets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Êàáåëè ðàäèî÷àñòîòíûå. . . . . . . . . . . . . . . . . . . . . . . . . . Coaxial radio-frequency cables. . . . . . . . . . . . . . . . . . . . . . . . . . 11
Ïðîâîäà è êàáåëè ìîíòàæíûå. . . . . . . . . . . . . . . . . . . . . Hook-up wires and cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Ïðîâîäà è êàáåëè àâèàêîñìè÷åñêèå. . . . . . . . . . . . . . . . Aerospace wires and cables. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Ïðîâîäà äëÿ òåðìîïàð . . . . . . . . . . . . . . . . . . . . . . . . . . . Wires for thermocouples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Àëôàâèòíûé ïåðå÷åíü ïðîäóêöèè. . . . . . . . . . . . . . . . . Alphabetic product index. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
ÎÁÌÎÒÎ×ÍÛÅ ÏÐÎÂÎÄÀ WINDING WIRES
ñ ýìàëåâîé èçîëÿöèåé with enamel insulation
ÏÝÒÂ-2
1. Êðóãëàÿ ìåäíàÿ ïðîâîëîêà. 1. Round copper wire.
2. Èçîëÿöèÿ èç ïîëèýôèðíîãî ëàêà. 2. Insulation - polyester enamel.
ÏÝÒÄ-180
1. Êðóãëàÿ ìåäíàÿ ïðîâîëîêà. 1. Round copper wire.
2. Èçîëÿöèÿ èç ïîëèýôèðèìèäíîãî ëàêà. 2. Insulation - polyesterimide enamel.
3. Èçîëÿöèÿ èç ïîëèàìèäèìèäíîãî ëàêà. 3. Insulation - polyamideimide enamel.
ÏÝÝÈÏ-1-155, ÏÝÝÈÏ-2-155
1. Ïðÿìîóãîëüíàÿ ìåäíàÿ ïðîâîëîêà. 1. Rectangular copper wire.
2. Èçîëÿöèÿ èç ïîëèýôèðèìèäíîãî ëàêà. 2. Insulation - polyesterimide enamel.
Ìàðêà Òåìïåðàòóðíûé Ðàçìåð, Ýëåìåíòû êîíñòðóêöèè Îáëàñòü ïðèìåíåíèÿ
è ñòàíäàðò èíäåêñ, °Ñ ìì
Type and Thermal Size, Elements of design Application
standard index, °Ñ mm
ÏÝÂÒË-1 120 ∅0,020-0,050 ìåäíàÿ ïðîâîëîêà, copper wire, Ïðîâîä ïðèìåíÿåòñÿ äëÿ èçãîòîâëåíèÿ Wire is used for the production of
ÒÓ 16-505.446-77 óòîíåííàÿ èçîëÿöèÿ insulation - îáìîòîê òåìïåðàòóðíîãî êëàññà "Å": class "E” windings: ignition coils,
èç ïîëèóðåòàíîâîãî polyurethane êàòóøåê çàæèãàíèÿ, òåëåôîííûõ êàïñþëåé, low-voltage dry transformers, relays,
ëàêà enamel íèçêîâîëüòíûõ ñóõèõ òðàíñôîðìàòîðîâ, solenoids, electrical machines and
(grade 1) ðåëå, ñîëåíîèäîâ, ýëåêòðè÷åñêèõ ìàøèí è apparatus, communication units,
àïïàðàòîâ, ðàäèîòåõíè÷åñêèõ èçäåëèé è micro-motors and other electronic
ÏÝÂÒË-2 120 ∅0,020-0,050 ìåäíàÿ ïðîâîëîêà, copper wire, ïðèáîðîâ, ìèêðîäâèãàòåëåé. Ïðîâîä units. Wire is solderable at 375°C
ÒÓ 16-505.446-77 èçîëÿöèÿ insulation - îáëàäàåò ñïîñîáíîñòüþ îáëóæèâàòüñÿ ïðè without preliminary removing of
èç ïîëèóðåòàíîâîãî polyurethane òåìïåðàòóðå +375°Ñ áåç ïðåäâàðèòåëüíîãî insulation. Wire is resistant to
ëàêà enamel óäàëåíèÿ èçîëÿöèè. Ïðîâîäà óñòîé÷èâû ê boiling water
(grade 2) êèïÿùåé âîäå
ÏÝÝÀ-130 130 ∅1,25-2,65 àëþìèíèåâàÿ aluminium wire, Ïðîâîä ïðèìåíÿåòñÿ äëÿ èçãîòîâëåíèÿ Wire is used for the production of
ÒÓ 16.Ê09-077-93 ïðîâîëîêà, insulation - polyester îáìîòîê òåìïåðàòóðíîãî êëàññà "Â": class "B” windings: low power
èçîëÿöèÿ èç enamel (grade 2) äâèãàòåëåé ìàëîé ìîùíîñòè è ñóõèõ motors and dry transformers
ïîëèýôèðíîãî ëàêà òðàíñôîðìàòîðîâ
ÏÝÒÂ-1 130 ∅0,063-1,60 ìåäíàÿ ïðîâîëîêà, copper wire, Ïðîâîä ïðèìåíÿåòñÿ äëÿ èçãîòîâëåíèÿ Wire is used for the production of
ÒÓ 16-705.110-79, óòîíåííàÿ èçîëÿöèÿ insulation - îáìîòîê òåìïåðàòóðíîãî êëàññà "Â": class "B" windings: measuring and
IEC 60317-34 èç ïîëèýôèðíîãî polyester enamel èçìåðèòåëüíûõ è ðåãèñòðèðóþùèõ registering units, communication
ëàêà (grade 1) ïðèáîðîâ, òåëåôîííûõ êàïñþëåé, equipment, low power motors,
äâèãàòåëåé ìàëîé ìîùíîñòè, electrical magnets and oil filled
ýëåêòðîìàãíèòîâ. transformers. Wire is resistant to
Óñòîé÷èâ ê ðàñòâîðèòåëÿì, òðàíñôîðìà- solvents, transformer oil and boiling
òîðíîìó ìàñëó è êèïÿùåé âîäå water
ÏÝÒÂ-2 130 ∅0,063-2,50 ìåäíàÿ ïðîâîëîêà, copper wire, Ïðîâîä ïðèìåíÿåòñÿ äëÿ èçãîòîâëåíèÿ Wire is used for the production of
ÒÓ 16-705.110-79, èçîëÿöèÿ èç insulation - îáìîòîê òåìïåðàòóðíîãî êëàññà "Â": class "B" windings: measuring and
IEC 60317-34 ïîëèýôèðíîãî ëàêà polyester enamel èçìåðèòåëüíûõ è ðåãèñòðèðóþùèõ registering units, communication
(grade 2) ïðèáîðîâ, òåëåôîííûõ êàïñþëåé, equipment, low power motors,
äâèãàòåëåé ìàëîé ìîùíîñòè, electrical magnets and dry
ýëåêòðîìàãíèòîâ è ñóõèõ transformers. Due to good
òðàíñôîðìàòîðîâ. Ïðîâîä îáëàäàåò mechanical properties of wire it can
îòëè÷íûìè ìåõàíè÷åñêèìè ñâîéñòâàìè, be used for mechanized winding.
ýòè ñâîéñòâà ïîçâîëÿþò èñïîëüçîâàòü Wire is resistant to solvents and
ïðîâîä äëÿ ìåõàíèçèðîâàííîé íàìîòêè. boiling water
Óñòîé÷èâ ê ðàñòâîðèòåëÿì è êèïÿùåé âîäå
ÏÝÒÂÌ 130 ∅0,250-1,400 ìåäíàÿ ïðîâîëîêà, copper wire, Ïðîâîä ïðèìåíÿåòñÿ äëÿ èçãîòîâëåíèÿ Wire is used for the production of
ÒÓ 16-505.370-78 óñèëåííàÿ èçîëÿöèÿ insulation - îáìîòîê òåìïåðàòóðíîãî êëàññà "Â": class "B" windings: low and
èç ïîëèýôèðíîãî polyester enamel äâèãàòåëåé ìàëîé è ñðåäíåé ìîùíîñòè, medium-power motors, generators
ëàêà (grade 3) ãåíåðàòîðîâ è ñóõèõ òðàíñôîðìàòîðîâ. and dry transformers. Due to the
Óëó÷øåííûå òåðìè÷åñêèå ñâîéñòâà â fact that thermal properties of wire
êëàññå "Â" ïðîâîäà îáåñïå÷èâàþò âûñîêóþ are better than average of "B" class
ñòåïåíü íàäåæíîñòè èçäåëèÿ ïðè wires, wire provide a high degree of
êðàòêîâðåìåííûõ íàãðóçêàõ. Ïðîâîä reliability of winding during short
îáëàäàåò îòëè÷íûìè ìåõàíè÷åñêèìè term overloads. Due to good
ñâîéñòâàìè, ïîçâîëÿþùèìè èñïîëüçîâàòü mechanical properties of wire it can
ïðîâîä äëÿ ìåõàíèçèðîâàííîé íàìîòêè. be used for mechanized winding.
Óñòîé÷èâ ê ðàñòâîðèòåëÿì Wire is resistant to solvents
2
Íîìåíêëàòóðíûé êàòàëîã. ×àñòü 4.
Ìàðêà Òåìïåðàòóðíûé Ðàçìåð, Ýëåìåíòû êîíñòðóêöèè Îáëàñòü ïðèìåíåíèÿ
è ñòàíäàðò èíäåêñ, °Ñ ìì
Type and Thermal Size, Elements of design Application
standard index, °Ñ mm
ÏÝÒÂÏ 130 "à" 0,80-3,55 ìåäíàÿ ïðîâîëîêà, copper wire, Ïðîâîä ïðèìåíÿåòñÿ äëÿ èçãîòîâëåíèÿ Wire is used for the production of
ÒÓ 16-705.457-87 "b" 2,00-12,50 èçîëÿöèÿ èç insulation - îáìîòîê òåìïåðàòóðíîãî êëàññà "Â": class "B" windings: universal
ïîëèýôèðíîãî ëàêà polyester enamel óíèâåðñàëüíûõ äâèãàòåëåé ñðåäíåé medium-power motors, generators,
ìîùíîñòè, ãåíåðàòîðîâ è ñóõèõ dry transformers. Rectangular
òðàíñôîðìàòîðîâ. Ïðÿìîóãîëüíàÿ ôîðìà shape provides the tight winding.
ïðîâîäà îáåñïå÷èâàåò âûñîêóþ ïëîòíîñòü Due to good mechanical properties
íàëîæåíèÿ ñëîåâ îáìîòêè. Ïðîâîä of wire it can be used for
îáëàäàåò õîðîøèìè ìåõàíè÷åñêèìè mechanized winding
ñâîéñòâàìè, ýòè ñâîéñòâà ïîçâîëÿþò
èñïîëüçîâàòü ïðîâîä äëÿ
ìåõàíèçèðîâàííîé íàìîòêè
ÏÝÝÀ-155 155 ∅1,25-2,65 àëþìèíèåâàÿ aluminium wire, Ïðîâîä ïðèìåíÿåòñÿ äëÿ èçãîòîâëåíèÿ Wire is used for the production of
ÒÓ 16-Ê71-001-87 ïðîâîëîêà, insulation - îáìîòîê òåìïåðàòóðíîãî êëàññà "F": class "F” windings: low and
èçîëÿöèÿ èç polyesterimide äâèãàòåëåé ìàëîé è ñðåäíåé ìîùíîñòè è medium power motors and dry
ïîëèýôèðèìèäíîãî enamel ñóõèõ òðàíñôîðìàòîðîâ transformers
ëàêà (grade 2)
ÏÝÂÒË-155 155 ∅0,28-1,50 ìåäíàÿ ïðîâîëîêà, copper wire, Ïðîâîä ïðèìåíÿåòñÿ äëÿ èçãîòîâëåíèÿ Wire is used for the production of
IEC 60317-20 èçîëÿöèÿ èç insulation - îáìîòîê òåìïåðàòóðíîãî êëàññà "F”: class "F” windings: ignition coils,
ÒÓ 16.Ê09-130-2003 ïîëèóðåòàíîâîãî polyurethane enamel êàòóøåê çàæèãàíèÿ, êàïñþëåé, low-voltage dry transformers,
ëàêà (grade 2) íèçêîâîëüòíûõ ñóõèõ òðàíñôîðìàòîðîâ, relays, solenoids, electrical
ðåëå, ñîëåíîèäîâ, ýëåêòðè÷åñêèõ ìàøèí è machines and apparatus,
àïïàðàòîâ, ðàäèîòåõíè÷åñêèõ èçäåëèé è communication units, micro-motors
ïðèáîðîâ, ìèêðîäâèãàòåëåé. Ïðîâîä and other electronic units. Wire is
îáëàäàåò ñïîñîáíîñòüþ îáëóæèâàòüñÿ ïðè solderable at 390°C without
òåìïåðàòóðå +390°Ñ áåç ïðåäâàðèòåëüíîãî preliminary removing of insulation
óäàëåíèÿ èçîëÿöèè
ÏÝÒ-155 155 ∅0,063-2,50 ìåäíàÿ ïðîâîëîêà, copper wire, Ïðîâîä ïðèìåíÿåòñÿ äëÿ èçãîòîâëåíèÿ Wire is used for the production of
ÒÓ 16.Ê71-160-92 èçîëÿöèÿ èç insulation - îáìîòîê òåìïåðàòóðíîãî êëàññà "F": class "F" windings: power motors,
ïîëèýôèðèìèäíîãî polyesterimide ñèëîâûõ äâèãàòåëåé øèðîêîãî ïðèìåíåíèÿ, motors for domestic electric
ëàêà enamel äâèãàòåëåé äëÿ äîìàøíèõ equipment and instruments,
(grade 2) ýëåêòðîïðèáîðîâ è ýëåêòðîèíñòðóìåíòîâ, generators, dry transformers,
ãåíåðàòîðîâ, ñóõèõ òðàíñôîðìàòîðîâ, measuring units, coils, relays.
èçìåðèòåëüíûõ ïðèáîðîâ, êàòóøåê è ðåëå. Wire is resistant to solvents
Ïðîâîä óñòîé÷èâ ê ðàñòâîðèòåëÿì
ÏÝÒÌ-155 155 ∅0,063-2,00 ìåäíàÿ ïðîâîëîêà, copper wire, Ïðîâîä ïðèìåíÿåòñÿ äëÿ èçãîòîâëåíèÿ Wire is used for the production of
ÒÓ 16-705.173-80, èçîëÿöèÿ èç insulation - îáìîòîê òåìïåðàòóðíîãî êëàññà "F": class "F" windings: power motors,
IEC 60317-3 ïîëèýôèðèìèäíîãî polyesterimide ñèëîâûõ äâèãàòåëåé øèðîêîãî ïðèìåíåíèÿ, motors for domestic electric
ëàêà enamel äâèãàòåëåé äëÿ äîìàøíèõ equipment and instruments,
(grade 3) ýëåêòðîïðèáîðîâ è ýëåêòðîèíñòðóìåíòîâ, generators, dry transformers,
ãåíåðàòîðîâ, ñóõèõ òðàíñôîðìàòîðîâ, measuring units, coils, relays. Due
èçìåðèòåëüíûõ ïðèáîðîâ, êàòóøåê è ðåëå. to good mechanical properties of
Ïðîâîä îáëàäàåò îòëè÷íûìè wire it can be used for mechanized
ìåõàíè÷åñêèìè ñâîéñòâàìè, ýòè ñâîéñòâà winding.
ïîçâîëÿþò èñïîëüçîâàòü ïðîâîä äëÿ Wire is resistant to solvents
ìåõàíèçèðîâàííîé íàìîòêè. Ïðîâîä
óñòîé÷èâ ê ðàñòâîðèòåëÿì
ÏÝÔ-155 155 ∅0,063-1,80 ìåäíàÿ ïðîâîëîêà, copper wire, Ïðîâîä ïðèìåíÿåòñÿ äëÿ èçãîòîâëåíèÿ Wire is used for the production of
ÒÓ 16-505.673-77, èçîëÿöèÿ èç insulation - îáìîòîê òåìïåðàòóðíîãî êëàññà "F": class "F" windings: motors of
IEC 60317-3 ïîëèýôèðèìèäíîãî polyesterimide äâèãàòåëåé êîìïðåññîðîâ õîëîäèëüíûõ compressors of refrigerators and
ëàêà enamel (grade 2) óñòàíîâîê è êîíäèöèîíåðîâ, ðàáîòàþùèõ â conditioners, operating in the
ñðåäå ôðåîíîâ (õëàäîíîâ). Ïðîâîä environment of freons (chladons),
óñòîé÷èâ ê ðàñòâîðèòåëÿì, as well as in oil-filled transformers.
òðàíñôîðìàòîðíîìó ìàñëó è ôðåîíàì Wire is resistant to solvents,
transformer oil and freons
ÏÝÝÈÏ-1-155 155 "à" 0,80-3,55 ìåäíàÿ ïðîâîëîêà, copper wire, Ïðîâîä ïðèìåíÿåòñÿ äëÿ èçãîòîâëåíèÿ Wire is used for the production of
ÒÓ 16-705.414-86, "b" 2,00-9,00 óòîíåííàÿ èçîëÿöèÿ insulation - îáìîòîê òåìïåðàòóðíîãî êëàññà "F”: class "F” windings: universal
IEC 60317-16 èç ïîëèýôèð- polyesterimide óíèâåðñàëüíûõ äâèãàòåëåé ñðåäíåé medium-power motors, generators,
èìèäíîãî ëàêà enamel (grade 1) ìîùíîñòè, ãåíåðàòîðîâ è ñóõèõ dry transformers. Rectangular
òðàíñôîðìàòîðîâ. Ïðÿìîóãîëüíàÿ ôîðìà shape provides the tight winding
ÏÝÝÈÏ-2-155 155 "à" 0,80-3,55 ìåäíàÿ ïðîâîëîêà, copper wire, ïðîâîäà îáåñïå÷èâàåò âûñîêóþ ïëîòíîñòü
ÒÓ 16-705.414-86, "b" 2,00-9,00 èçîëÿöèÿ èç insulation - íàëîæåíèÿ ñëîåâ îáìîòêè
IEC 60317-16 ïîëèýôèðèìèäíîãî polyesterimide
ëàêà enamel (grade 2)
ÏÝÒ-180 180 ∅0,063-2,50 ìåäíàÿ ïðîâîëîêà, copper wire, Ïðèìåíÿåòñÿ äëÿ èçãîòîâëåíèÿ îáìîòîê Wire is used for the production of
ÒÓ 16.Ê09-097-95, èçîëÿöèÿ èç insulation - òåìïåðàòóðíîãî êëàññà "Í": äâèãàòåëåé è class "H" windings: motors and dry
IEC 60317-8 ïîëèýôèðèìèäíîãî polyesterimide ñóõèõ òðàíñôîðìàòîðîâ transformers, industrial and
ëàêà enamel (grade 2) ýëåêòðîîáîðóäîâàíèÿ äëÿ ïðîìûøëåííîãî domestic electric equipment,
è áûòîâîãî ïðèìåíåíèÿ, ãåíåðàòîðîâ, generators, measuring units, coils,
èçìåðèòåëüíûõ ïðèáîðîâ, êàòóøåê, ðåëå, relays
àïïàðàòóðû ñâÿçè
3
Ìàðêà Òåìïåðàòóðíûé Ðàçìåð, Ýëåìåíòû êîíñòðóêöèè Îáëàñòü ïðèìåíåíèÿ
è ñòàíäàðò èíäåêñ, °Ñ ìì
Type and Thermal Size, Elements of design Application
standard index, °Ñ mm
ÏÝÒÄ-180 180 ∅0,28-1,50 ìåäíàÿ ïðîâîëîêà, copper wire, Ïðîâîä ïðèìåíÿåòñÿ äëÿ èçãîòîâëåíèÿ Wire is used for the production of
ÒÓ 16-705.264-82, èçîëÿöèÿ èç 2 ñëîåâ insulation - îáìîòîê òåìïåðàòóðíîãî êëàññà "Í": class "H" windings: motors and dry
IEC 60317-22 ïîëèýôèðèìèäíîãî polyesterimide äâèãàòåëåé è ñóõèõ òðàíñôîðìàòîðîâ transformers, industrial and
è ïîëèàìèäèìèä- enamel ýëåêòðîîáîðóäîâàíèÿ äëÿ domestic electric equipment,
íîãî ëàêà (grade 2), ïðîìûøëåííîãî è áûòîâîãî ïðèìåíåíèÿ, generators, measuring units, coils,
insulation - ãåíåðàòîðîâ, èçìåðèòåëüíûõ ïðèáîðîâ, relays, communication apparatus.
polyamideimide êàòóøåê, ðåëå, àïïàðàòóðû ñâÿçè. Due to excellent electric and
enamel Áëàãîäàðÿ ïðåâîñõîäíûì ýëåêòðè÷åñêèì thermal properties as well as
(grade 2) è òåìïåðàòóðíûì ñâîéñòâàì, à òàêæå resistance to chemicals, wire
óñòîé÷èâîñòè ê õèìè÷åñêèì âåùåñòâàì, provides high reliability to windings
îáåñïå÷èâàåò âûñîêóþ ñòåïåíü and is used for production of
íàäåæíîñòè èçäåëèé è èñïîëüçóåòñÿ â explosion-proof equipment for
èçãîòîâëåíèè âçðûâîçàùèùåííîãî chemical, oil and gas and coal
îáîðóäîâàíèÿ äëÿ õèìè÷åñêîé, ãàçîâîé, industries. Mechanical strength of
íåôòåïåðåðàáàòûâàþùåé è óãîëüíîé insulation provides wire to be used
ïðîìûøëåííîñòè. Ìåõàíè÷åñêàÿ for automatic winding. Wire is
ïðî÷íîñòü èçîëÿöèè ïðîâîäà ïîçâîëÿåò resistant to solvents
èñïîëüçîâàòü åãî ïðè àâòîìàòè÷åñêîé
íàìîòêå.
Óñòîé÷èâ ê ðàñòâîðèòåëÿì
ÏÝÒÊÄ-180 180 ∅0,28-1,50 ìåäíàÿ ïðîâîëîêà, copper wire, Ïðîâîä ïðèìåíÿåòñÿ äëÿ èçãîòîâëåíèÿ Wire is used for making frameless
ÒÓ 16.Ê09-132-2003 èçîëÿöèÿ èç insulation - áåñêàðêàñíûõ êàòóøåê îòêëîíÿþùèõ coils for diffraction systems of TV-
IEC 60317-37 ïîëèýôèðèìèäíîãî polyesterimide ñèñòåì òåëåâèçîðîâ, â êàòóøêàõ sets, for coils of measuring units,
ëàêà, enamel, additional èçìåðèòåëüíûõ ïðèáîðîâ, îáìîòêàõ ðåëå, relays windings, electric motors,
äîïîëíèòåëüíûé bonding layer based ýëåêòðîäâèãàòåëåé, íåáîëüøèõ small transformers, magnetic coils
êëåÿùèé ñëîé íà on aromatic òðàíñôîðìàòîðàõ, â ýëåêòðîìàãíèòíûõ
îñíîâå polyamide êàòóøêàõ
àðîìàòè÷åñêîãî
ïîëèàìèäà
ÏÝÝÈÏ-1-800 180 "à" 0,80-3,55 ìåäíàÿ ïðîâîëîêà, copper wire, Ïðîâîä ïðèìåíÿåòñÿ äëÿ èçãîòîâëåíèÿ Wire is used for the production of
ÌÝÊ 60317-28 "b" 2,00-9,00 óòîíåííàÿ èçîëÿöèÿ insulation - îáìîòîê òåìïåðàòóðíîãî êëàññà "H”: class "H” windings: universal
èç ïîëèýôèðèìèä- polyesterimide óíèâåðñàëüíûõ äâèãàòåëåé ñðåäíåé medium-power motors, generators,
íîãî ëàêà enamel (grade 1) ìîùíîñòè, ãåíåðàòîðîâ è ñóõèõ dry transformers. Rectangular
òðàíñôîðìàòîðîâ. Ïðÿìîóãîëüíàÿ ôîðìà shape provides the tight winding
ÏÝÝÈÏ-2-180 180 "à" 0,80-3,55 ìåäíàÿ ïðîâîëîêà, copper wire, ïðîâîäà îáåñïå÷èâàåò âûñîêóþ
ÌÝÊ 60317-28 "b" 2,00-9,00 èçîëÿöèÿ èç insulation - ïëîòíîñòü íàëîæåíèÿ ñëîåâ îáìîòêè
ïîëèýôèðèìèäíîãî polyesterimide
ëàêà enamel (grade 2)
ÏÝÒ-1-200 200 ∅0,28-2,50 ìåäíàÿ ïðîâîëîêà, copper wire, Ïðîâîä ïðèìåíÿåòñÿ äëÿ èçãîòîâëåíèÿ Wire is used for the production of
ÒÓ 16-505.937-76 èçîëÿöèÿ èç polyamideimide îáìîòîê òåìïåðàòóðíîãî êëàññà "Ñ": class "C" windings: power and
IEC 60317-26 ïîëèàìèäèìèäíîãî enamel ñèëîâûõ è òÿãîâûõ äâèãàòåëåé, ñóõèõ traction motors, dry transformers,
ëàêà (òèï 1) (grade 1) òðàíñôîðìàòîðîâ, ãåíåðàòîðîâ, generators, measuring units, coils,
èçìåðèòåëüíûõ ïðèáîðîâ, êàòóøåê, ðåëå relays
ÏÝÒ-2-200 200 ∅0,28-2,50 ìåäíàÿ ïðîâîëîêà, copper wire,
è àïïàðàòóðû ñâÿçè
ÒÓ 16-505.937-76 èçîëÿöèÿ èç polyamideimide
IEC 60317-26 ïîëèàìèäèìèäíîãî enamel
ëàêà (òèï 2) (grade 2)
ÏÝÝÈÄ-1-200 200 ∅0,28-1,50 ìåäíàÿ ïðîâîëîêà, copper wire, Ïðîâîä ïðèìåíÿåòñÿ äëÿ èçãîòîâëåíèÿ Wire is used for the production of
ÒÓ 16.Ê71-250-95, óòîíåííàÿ èçîëÿöèÿ insulation - îáìîòîê òåìïåðàòóðíîãî êëàññà "Ñ": class "C" windings: power and
IEC 60317-13 èç 2 ñëîåâ polyesterimide ñèëîâûõ è òÿãîâûõ äâèãàòåëåé, ñóõèõ traction motors, dry transformers,
ïîëèýôèðèìèäíîãî enamel (grade 1), òðàíñôîðìàòîðîâ, ãåíåðàòîðîâ, generators, measuring units, coils,
ëàêà, èçîëÿöèÿ èç insulation - èçìåðèòåëüíûõ ïðèáîðîâ, êàòóøåê, ðåëå. relays and communication
ïîëèàìèäèìèäíîãî polyamideimide Áëàãîäàðÿ âûñîêèì ýëåêòðè÷åñêèì, apparatus, as well as refrigerators
ëàêà enamel (grade 1) òåìïåðàòóðíûì ñâîéñòâàì, à òàêæå and conditioners, operating in
óñòîé÷èâîñòè ê àãðåññèâíûì ñðåäàì: chladone environment. Due to high
êèñëîòàì, ðàñòâîðèòåëÿì, è ìàñëàì electric and thermal properties and
ÏÝÝÈÄ-2-200 200 ∅0,28-1,50 ìåäíàÿ ïðîâîëîêà, copper wire, ïðîâîä îáåñïå÷èâàåò âûñîêóþ ñòåïåíü resistance to aggressive
ÒÓ 16.Ê71-250-95, èçîëÿöèÿ èç 2 ñëîåâ insulation - íàäåæíîñòè èçäåëèé è èñïîëüçóåòñÿ â environment, like acids, solvents,
IEC 60317-13 ïîëèýôèðèìèäíîãî polyesterimide èçãîòîâëåíèè âçðûâîçàùèùåííîãî oils and freons, wire provides high
ëàêà, èçîëÿöèÿ èç enamel (grade 2), îáîðóäîâàíèÿ äëÿ õèìè÷åñêîé, ãàçîâîé, reliability to windings and is used for
ïîëèàìèäèìèäíîãî insulation - íåôòåïåðåðàáàòûâàþùåé è óãîëüíîé production of explosionproof
ëàêà polyamideimide ïðîìûøëåííîñòè. Èñêëþ÷èòåëüíàÿ equipment for chemical, oil and gas
enamel (grade 2) ìåõàíè÷åñêàÿ ïðî÷íîñòü èçîëÿöèè and coal industries. The outstanding
ïîçâîëÿåò èñïîëüçîâàòü ïðîâîä ïðè mechanical strength of insulation of
àâòîìàòè÷åñêîé íàìîòêå wire provides the wire to be used
for automatic winding
4
Íîìåíêëàòóðíûé êàòàëîã. ×àñòü 4.
ÎÁÌÎÒÎ×ÍÛÅ ÏÐÎÂÎÄÀ WINDING WIRES
ñî ñòåêëîâîëîêíèñòîé èçîëÿöèåé with glass-fiber insulation
ÏÑÄÒ
1. Êðóãëàÿ èëè ïðÿìîóãîëüíàÿ 1. Round or rectangular aluminium wire.
àëþìèíèåâàÿ ïðîâîëîêà. 2. Thinned insulation - two-ply
2. Èçîëÿöèÿ èç äâóõ ñëîåâ ñòåêëîïîëèýôèðíûõ íèòåé, of glass-fiber with shimming
ñ ïîäêëåéêîé è ïðîïèòêîé ýëåêòðîèçîëÿöèîííûì and impregnation of electroinsulating
êðåìíèéîðãàíè÷åñêèì ëàêîì. glyptal lacquer.
ÏÑÄÊÒ
1. Êðóãëàÿ èëè ïðÿìîóãîëüíàÿ 1. Round or rectangular copper wire.
ìåäíàÿ ïðîâîëîêà. 2. Thinned insulation - two-ply of
2. Óòîíåííàÿ èçîëÿöèÿ glass-fiber with shimming and
èç äâóõ ñëîåâ ñòåêëÿííûõ íèòåé, impregnation of electroinsulating
ñ ïîäêëåéêîé è ïðîïèòêîé silicone lacquer.
ýëåêòðîèçîëÿöèîííûì
êðåìíèéîðãàíè÷åñêèì ëàêîì.
AÏÑËÄÊÒ
1. Êðóãëàÿ èëè ïðÿìîóãîëüíàÿ 1. Round or rectangular aluminium wire.
àëþìèíèåâàÿ ïðîâîëîêà. 2. Thinned insulation - two-ply of polyester-
2. Óòîíåííàÿ èçîëÿöèÿ fiber with shimming and impregnation
èç äâóõ ñëîåâ ñòåêëîïîëèýôèðíûõ íèòåé, of electroinsulating silicone lacquer.
ñ ïîäêëåéêîé è ïðîïèòêîé ýëåêòðîèçîëÿöèîííûì
êðåìíèéîðãàíè÷åñêèì ëàêîì.
Ìàðêà Òåìïåðàòóðíûé Ðàçìåð, Ýëåìåíòû êîíñòðóêöèè Îáëàñòü ïðèìåíåíèÿ
è ñòàíäàðò èíäåêñ, °Ñ ìì
Type and Thermal Size, Elements of design Application
standard index, °Ñ mm
ÀÏÑÄ 155 ∅1,00-5,00 àëþìèíèåâàÿ aluminium wire, Ïðîâîä ïðèìåíÿåòñÿ äëÿ èçãîòîâëåíèÿ Wire is used for the production of
ÒÓ 16.Ê71-257-96, "à" 1,80-5,60 ïðîâîëîêà, insulation - two-ply îáìîòîê òåìïåðàòóðíîãî êëàññà "F": class "F" windings: motors,
ÒÒ "b" 3,35-14,00 èçîëÿöèÿ èç äâóõ of glass-fiber with äâèãàòåëåé, òðàíñôîðìàòîðîâ, transformers, generators, welding
ñëîåâ ñòåêëÿííûõ shimming and ãåíåðàòîðîâ, ýëåêòðîñâàðî÷íîãî equipment and switchgears
íèòåé, ñ ïîäêëåéêîé impregnation of îáîðóäîâàíèÿ è ýëåêòðè÷åñêîé ïóñêîâîé
è ïðîïèòêîé electroinsulating àïïàðàòóðû
ýëåêòðîèçîëÿöèîí- glyptal lacquer
íûì ãëèôòàëåâûì
ëàêîì
ÀÏÑËÄ 155 ∅1,00-5,00 àëþìèíèåâàÿ aluminium wire, Ïðîâîä ïðèìåíÿåòñÿ äëÿ èçãîòîâëåíèÿ Wire is used for the production of
ÒÓ 16.Ê71-257-96, "à" 1,80-5,60 ïðîâîëîêà, insulation - two-ply îáìîòîê òåìïåðàòóðíîãî êëàññà "F": class "F" windings: transformers
TT "b" 3,35-14,00 èçîëÿöèÿ èç äâóõ of polyester-fiber ãåíåðàòîðîâ è òðàíñôîðìàòîðîâ. Ïðîâîä and generators. Wire is resistant to
ñëîåâ ñòåêëî- with shimming and óñòîé÷èâ ê âîçäåéñòâèþ ìåõàíè÷åñêèõ mechanical loads during
ïîëèýôèðíûõ impregnation of íàãðóçîê â ïðîöåññå èçãîòîâëåíèÿ è manufacturing and operation of the
íèòåé, ñ ïîäêëåéêîé electroinsulating ýêñïëóàòàöèè îáîðóäîâàíèÿ equipment
è ïðîïèòêîé glyptal lacquer
ýëåêòðîèçîëÿöèîí-
íûì ãëèôòàëåâûì
ëàêîì
ÀÏÑÄÊÒ 200 ∅1,00-5,00 àëþìèíèåâàÿ aluminium wire, Ïðîâîä ïðèìåíÿåòñÿ äëÿ èçãîòîâëåíèÿ Wire is used for the production of
ÒÓ 16.Ê71-257-96 "à" 1,80-5,60 ïðîâîëîêà, thinned insulation - îáìîòîê òåìïåðàòóðíîãî êëàññà "C": class "C" windings: motors,
"b" 3,55-14,00 óòîíåííàÿ èçîëÿöèÿ two-ply of glass- äâèãàòåëåé, òðàíñôîðìàòîðîâ, transformers, generators, welding
èç äâóõ ñëîåâ fiber with shimming ãåíåðàòîðîâ, ýëåêòðîñâàðî÷íîãî equipment and switchgears. Good
ñòåêëÿííûõ íèòåé, and impregnation îáîðóäîâàíèÿ è ýëåêòðè÷åñêîé ïóñêîâîé thermal properties of wire make it
ñ ïîäêëåéêîé è of electroinsulating àïïàðàòóðû. Áëàãîäàðÿ òåðìè÷åñêèì possible to use wires in windings of
ïðîïèòêîé ýëåêòðî- silicone lacquer ñâîéñòâàì ïðîâîä èñïîëüçóåòñÿ â equipment subject to long-term
èçîëÿöèîííûì èçãîòîâëåíèè îáìîòîê îáîðóäîâàíèÿ, overloads during operation
êðåìíèéîðãàíè÷å- ïîäâåðãàåìîãî äëèòåëüíûì ïåðåãðóçêàì â
ñêèì ëàêîì ïðîöåññå ýêñïëóàòàöèè
ÀÏÑÄÊ 200 ∅1,00-5,00 àëþìèíèåâàÿ aluminium wire,
ÒÓ 16.Ê71-257-96 "à" 1,80-5,60 ïðîâîëîêà, insulation - two-ply
"b" 3,55-14,00 èçîëÿöèÿ èç äâóõ of glass-fiber with
ñëîåâ ñòåêëÿííûõ shimming and
íèòåé, ñ ïîäêëåéêîé impregnation
è ïðîïèòêîé of electroinsulating
ýëåêòðî- silicone lacquer
èçîëÿöèîííûì
êðåìíèéîðãàíè÷å-
ñêèì ëàêîì
5
Ìàðêà Òåìïåðàòóðíûé Ðàçìåð, Ýëåìåíòû êîíñòðóêöèè Îáëàñòü ïðèìåíåíèÿ
è ñòàíäàðò èíäåêñ, °Ñ ìì
Type and Thermal Size, Elements of design Application
standard index, °Ñ mm
ÀÏÑËÄÊÒ 200 ∅1,00-5,00 àëþìèíèåâàÿ aluminium wire, Ïðîâîä ïðèìåíÿåòñÿ äëÿ èçãîòîâëåíèÿ Wire is used for the production of
ÒÓ 16.Ê71-257-96 "à" 1,80-5,60 ïðîâîëîêà, thinned insulation - îáìîòîê òåìïåðàòóðíîãî êëàññà "C": class "C" windings: motors,
"b" 3,55-14,00 óòîíåííàÿ èçîëÿöèÿ two-ply of polyester- äâèãàòåëåé, òðàíñôîðìàòîðîâ, transformers, generators, welding
èç äâóõ ñëîåâ fiber with shimming ãåíåðàòîðîâ, ýëåêòðîñâàðî÷íîãî equipment and switchgears. Good
ñòåêëîïîëèýôèðíûõ and impregnation îáîðóäîâàíèÿ è ýëåêòðè÷åñêîé ïóñêîâîé thermal properties of wire make it
íèòåé, ñ ïîäêëåéêîé of electroinsulating àïïàðàòóðû. Áëàãîäàðÿ òåðìè÷åñêèì possible to use wires in windings of
è ïðîïèòêîé silicone lacquer ñâîéñòâàì ïðîâîä èñïîëüçóåòñÿ â equipment subject to long-term
ýëåêòðîèçîëÿöèîí- èçãîòîâëåíèè îáìîòîê îáîðóäîâàíèÿ, overloads during operation.
íûì êðåìíèéîð- ïîäâåðãàåìîãî äëèòåëüíûì ïåðåãðóçêàì â Wire is resistant to mechanical
ãàíè÷åñêèì ëàêîì ïðîöåññå ýêñïëóàòàöèè. Ïðîâîä óñòîé÷èâ ê loads during manufacturing and
âîçäåéñòâèþ ìåõàíè÷åñêèõ íàãðóçîê â operation of the equipment
ÀÏÑËÄÊ 200 ∅1,00-5,00 àëþìèíèåâàÿ aluminium wire, ïðîöåññå èçãîòîâëåíèÿ è ýêñïëóàòàöèè
ÒÓ 16.Ê71-257-96 "à" 1,80-5,60 ïðîâîëîêà, insulation - two-ply îáîðóäîâàíèÿ
"b" 3,55-14,00 èçîëÿöèÿ èç äâóõ of polyester-fiber with
ñëîåâ ñòåêëî- shimming and
ïîëèýôèðíûõ impregnation
íèòåé, ñ ïîäêëåéêîé of electroinsulating
è ïðîïèòêîé silicone lacquer
ýëåêòðîèçîëÿöèîí-
íûì êðåìíèéîðãà-
íè÷åñêèì ëàêîì
ÏÑÄÒ 155 ∅1,00-5,20 ìåäíàÿ ïðîâîëîêà, copper wire, Ïðîâîä ïðèìåíÿåòñÿ äëÿ èçãîòîâëåíèÿ Wire is used for the production of
ÒÓ 16.Ê71-129-91 "à" 0,90-5,60 óòîíåííàÿ èçîëÿöèÿ thinned insulation - îáìîòîê òåìïåðàòóðíîãî êëàññà "F": class "F" windings: motors,
"b" 2,12-12,50 èç äâóõ ñëîåâ two-ply of glass- äâèãàòåëåé, òðàíñôîðìàòîðîâ, transformers, generators,
ñòåêëÿííûõ íèòåé, fiber with shimming ãåíåðàòîðîâ, òóðáîãåíåðàòîðîâ, àïïàðàòîâ turbogenerators, instruments and
ñ ïîäêëåéêîé è and impregnation of è ïðèáîðîâ appliances
ïðîïèòêîé ýëåêòðî- electroinsulating
èçîëÿöèîííûì glyptal lacquer
ãëèôòàëåâûì ëàêîì
ÏÑÄÒ-Ë 155 ∅1,00-5,20 ìåäíàÿ ïðîâîëîêà, copper wire,
ÒÓ 16.Ê71-129-91 "à" 0,90-5,60 óòîíåííàÿ èçîëÿöèÿ thinned insulation -
"b" 2,12-12,50 èç äâóõ ñëîåâ two-ply of glass-
ñòåêëÿííûõ íèòåé, fiber with shimming
ñ ïîäêëåéêîé è and impregnation of
ïðîïèòêîé ýëåêòðî- electroinsulating
èçîëÿöèîííûì glyptal lacquer,
ãëèôòàëåâûì lacquer covering
ëàêîì,
ëàêîâîå ïîêðûòèå
ÏÑÄ 155 ∅1,00-5,20 ìåäíàÿ ïðîâîëîêà, copper wire, Òàê æå, êàê ÏÑÄÒ, íî óëó÷øåííûå The same as ÏÑÄÒ, but improved
ÒÓ 16.Ê09-010-2005 "à" 0,90-5,60 èçîëÿöèÿ èç äâóõ insulation - two-ply ýëåêòðè÷åñêèå ñâîéñòâà ïðîâîäà electrical properties of wire make it
"b" 2,12-12,50 ñëîåâ ñòåêëÿííûõ of glass-fiber with ïîçâîëÿþò èñïîëüçîâàòü ïðîâîä â possible to use wires in windings
íèòåé, ñ ïîäêëåéêîé shimming and îáìîòêàõ, ïîäâåðæåííûõ êðàòêîâðåìåííûì subject to short-term overloads
è ïðîïèòêîé impregnation of ïåðåãðóçêàì â ïðîöåññå ýêñïëóàòàöèè during operation
ýëåêòðî- electroinsulating
èçîëÿöèîííûì glyptal lacquer
ãëèôòàëåâûì ëàêîì
ÏÑÄ-Ë 155 ∅1,00-5,20 ìåäíàÿ ïðîâîëîêà, copper wire,
ÒÓ 16.Ê71-129-91 "à" 0,90-5,60 èçîëÿöèÿ èç äâóõ insulation - two-ply
"b" 2,12-12,50 ñëîåâ ñòåêëÿííûõ of glass-fiber with
íèòåé, ñ ïîäêëåéêîé shimming and
è ïðîïèòêîé impregnation of
ýëåêòðî- electroinsulating
èçîëÿöèîííûì glyptal lacquer,
ãëèôòàëåâûì lacquer covering
ëàêîì, ëàêîâîå
ïîêðûòèå
ÏÑÄ-1 155 ∅1,00-5,20 ìåäíàÿ ïðîâîëîêà, copper wire, Òàê æå, êàê ÏÑÄ, íî ãîòîâàÿ îáìîòêà The same as ÏÑÄ, but the winding
ÃÎÑÒ 22301-77 "à" 0,90-5,60 èçîëÿöèÿ èç äâóõ insulation - two-ply îáëàäàåò ëó÷øåé ñîâìåñòèìîñòüþ ñ will have better compatibility with
"b" 2,12-12,50 ñëîåâ ñòåêëÿííûõ of glass-fiber ïðîïèòûâàþùèìè ñîñòàâàìè impregnating compaunds
íèòåé, ñ ïîäêëåéêîé with shimming and
è ïðîïèòêîé impregnation of
ýëåêòðî- electroinsulating
èçîëÿöèîííûì epoxy lacquer
ýïîêñèäíûì ëàêîì
ÏÑËÄÒ 155 ∅1,00-5,00 ìåäíàÿ ïðîâîëîêà, copper wire, Ïðîâîä ïðèìåíÿåòñÿ äëÿ èçãîòîâëåíèÿ Wire is used for the production of
ÒÓ 16.Ê71-129-91 "à" 0,90-5,60 óòîíåííàÿ èçîëÿöèÿ thinned insulation - îáìîòîê òåìïåðàòóðíîãî êëàññà "F": class "F" windings: transformers
"b" 2,12-12,50 èç äâóõ ñëîåâ two-ply of polyester- ãåíåðàòîðîâ è òðàíñôîðìàòîðîâ. Ïðîâîä and generators. Wire is resistant to
ñòåêëîïîëèýôèðíûõ fiber with shimming óñòîé÷èâ ê âîçäåéñòâèþ ìåõàíè÷åñêèõ mechanical loads during
íèòåé, ñ ïîäêëåéêîé and impregnation of íàãðóçîê â ïðîöåññå èçãîòîâëåíèÿ è manufacturing and operation of the
è ïðîïèòêîé electroinsulating ýêñïëóàòàöèè îáîðóäîâàíèÿ equipment
ýëåêòðî- glyptal lacquer
èçîëÿöèîííûì
ãëèôòàëåâûì ëàêîì
6
Íîìåíêëàòóðíûé êàòàëîã. ×àñòü 4.
Ìàðêà Òåìïåðàòóðíûé Ðàçìåð, Ýëåìåíòû êîíñòðóêöèè Îáëàñòü ïðèìåíåíèÿ
è ñòàíäàðò èíäåêñ, °Ñ ìì
Type and Thermal Size, Elements of design Application
standard index, °Ñ mm
ÏÑËÄ 155 ∅1,00-5,00 ìåäíàÿ ïðîâîëîêà, copper wire, Òàê æå, êàê ÏÑËÄÒ, íî óëó÷øåííûå The same as for ÏÑËÄÒ, but
ÒÓ 16.Ê71-129-91 "à" 0,90-5,60 èçîëÿöèÿ èç äâóõ insulation - two-ply ýëåêòðè÷åñêèå ñâîéñòâà ïðîâîäà improved electrical properties of
"b" 2,12-12,50 ñëîåâ of polyester-fiber ïîçâîëÿþò èñïîëüçîâàòü ïðîâîä â wire make it possible to use wires
ñòåêëîïîëèýôèðíûõ with shimming îáìîòêàõ ïîäâåðæåííûõ êðàòêîâðåìåííûì in windings subject to short-term
íèòåé, ñ ïîäêëåéêîé and impregnation of ïåðåãðóçêàì â ïðîöåññå ýêñïëóàòàöèè overloads during operation
è ïðîïèòêîé electroinsulating
ýëåêòðî- glyptal lacquer
èçîëÿöèîííûì
ãëèôòàëåâûì ëàêîì
ÏÑÄÊÒ 200 ∅1,00-5,20 ìåäíàÿ ïðîâîëîêà, copper wire, Ïðîâîä ïðèìåíÿåòñÿ äëÿ èçãîòîâëåíèÿ Wire is used for the production of
ÒÓ 16.Ê71-129-91 "à" 0,90-5,60 óòîíåííàÿ èçîëÿöèÿ thinned insulation - îáìîòîê òåìïåðàòóðíîãî êëàññà "C": class "C" windings: transformers,
"b" 2,12-12,50 èç äâóõ ñëîåâ two-ply of glass- òðàíñôîðìàòîðîâ, ãèäðîãåíåðàòîðîâ è hydro-generators and electric
ñòåêëÿííûõ íèòåé, fiber with shimming ýëåêòðîäâèãàòåëåé. Áëàãîäàðÿ motors. Good thermal properties of
ñ ïîäêëåéêîé è and impregnation of òåðìè÷åñêèì ñâîéñòâàì ïðîâîä wire make it possible to use wires
ïðîïèòêîé ýëåêòðî- electroinsulating èñïîëüçóåòñÿ â èçãîòîâëåíèè îáìîòîê in windings of machines subject to
èçîëÿöèîííûì silicone lacquer îáîðóäîâàíèÿ, ïîäâåðãàåìîãî äëèòåëüíûì long-term overloads during
êðåìíèéîðãàíè÷åñ- ïåðåãðóçêàì â ïðîöåññå ýêñïëóàòàöèè operation
êèì ëàêîì
ÏÑÄÊÒ-Ë 200 ∅1,00-5,20 ìåäíàÿ ïðîâîëîêà, copper wire,
ÒÓ 16.Ê71-129-91 "à" 0,90-5,60 óòîíåííàÿ èçîëÿöèÿ thinned insulation -
"b" 2,12-12,50 èç äâóõ ñëîåâ two-ply of glass-
ñòåêëÿííûõ íèòåé, fiber with shimming
ñ ïîäêëåéêîé è and impregnation of
ïðîïèòêîé ýëåêòðî- electroinsulating
èçîëÿöèîííûì silicone lacquer,
êðåìíèéîðãàíè÷åñ- lacquer covering
êèì ëàêîì,
ëàêîâîå ïîêðûòèå
ÏÑÄÊ 200 ∅1,00-5,20 ìåäíàÿ ïðîâîëîêà, copper wire, Ïðîâîä ïðèìåíÿåòñÿ äëÿ èçãîòîâëåíèÿ Wire is used for the production of
ÒÓ 16.Ê09-010-2005 "à" 0,90-5,60 èçîëÿöèÿ èç äâóõ insulation - two-ply îáìîòîê òåìïåðàòóðíîãî êëàññà "C": class "C" windings: transformers,
"b" 2,12-12,50 ñëîåâ ñòåêëÿííûõ of glass-fiber with òðàíñôîðìàòîðîâ, ãèäðîãåíåðàòîðîâ è hydro-generators and electric
íèòåé, ñ ïîäêëåéêîé shimming and ýëåêòðîäâèãàòåëåé. Áëàãîäàðÿ motors. Good thermal and electric
è ïðîïèòêîé impregnation of òåðìè÷åñêèì è ýëåêòðè÷åñêèì ñâîéñòâàì properties of wire make it possible
ýëåêòðî- electroinsulating ïðîâîä èñïîëüçóåòñÿ â èçãîòîâëåíèè to use wires in windings of
èçîëÿöèîííûì silicone lacquer îáìîòîê îáîðóäîâàíèÿ, ïîäâåðãàåìîãî machines subject to long-term
êðåìíèéîðãàíè÷åñ- äëèòåëüíûì ïåðåãðóçêàì â ïðîöåññå overloads during operation
êèì ëàêîì ýêñïëóàòàöèè
ÏÑËÄÊÒ 200 ∅1,00-5,20 ìåäíàÿ ïðîâîëîêà, copper wire, Ïðèìåíÿåòñÿ äëÿ èçãîòîâëåíèÿ îáìîòîê Wire is used for the production of
ÒÓ 16.Ê71-129-91 "à" 0,90-5,60 óòîíåííàÿ èçîëÿöèÿ thinned insulation - òåìïåðàòóðíîãî êëàññà "C": class "C" windings: transformers,
"b" 2,12-12,50 èç äâóõ ñëîåâ two-ply of polyester- òðàíñôîðìàòîðîâ, ãèäðîãåíåðàòîðîâ è hydro-generators and electric
ñòåêëîïîëèýôèðíûõ fiber with shimming ýëåêòðîäâèãàòåëåé. Áëàãîäàðÿ motors. Good thermal properties of
íèòåé, ñ ïîäêëåéêîé and impregnation of òåðìè÷åñêèì ñâîéñòâàì ïðîâîä wire make it possible to use wires
è ïðîïèòêîé electroinsulating èñïîëüçóåòñÿ â èçãîòîâëåíèè îáìîòîê in windings of machines subject to
ýëåêòðî- silicone lacquer îáîðóäîâàíèÿ, ïîäâåðãàåìîãî äëèòåëüíûì long-term overloads during
èçîëÿöèîííûì ïåðåãðóçêàì â ïðîöåññå ýêñïëóàòàöèè. operation. Wire is resistant to
êðåìíèéîðãàíè÷åñ- Óñòîé÷èâ ê âîçäåéñòâèþ ìåõàíè÷åñêèõ mechanical loads during
êèì ëàêîì íàãðóçîê â ïðîöåññå èçãîòîâëåíèÿ è manufacturing and operation of the
ýêñïëóàòàöèè îáîðóäîâàíèÿ equipment
ÏÑËÄÊ 200 ∅1,00-5,20 ìåäíàÿ ïðîâîëîêà, copper wire, Ïðîâîä ïðèìåíÿåòñÿ äëÿ èçãîòîâëåíèÿ Wire is used for the production of
ÒÓ 16.Ê71-129-91 "à" 0,90-5,60 èçîëÿöèÿ èç äâóõ insulation - two-ply îáìîòîê òåìïåðàòóðíîãî êëàññà "C": class "C" windings: transformers,
"b" 2,12-12,50 ñëîåâ ñòåêëî- of polyester-fiber òðàíñôîðìàòîðîâ, ãèäðîãåíåðàòîðîâ è hydro-generators and electric
ïîëèýôèðíûõ with shimming and ýëåêòðîäâèãàòåëåé. Áëàãîäàðÿ motors. Good thermal and electric
íèòåé, ñ ïîäêëåéêîé impregnation of òåðìè÷åñêèì è ýëåêòðè÷åñêèì ñâîéñòâàì properties of wire make it possible
è ïðîïèòêîé electroinsulating ïðîâîä èñïîëüçóåòñÿ â èçãîòîâëåíèè to use wires in windings of
ýëåêòðîèçîëÿöèîí- silicone lacquer îáìîòîê îáîðóäîâàíèÿ, ïîäâåðãàåìîãî machines subject to long-term
íûì êðåìíèé- äëèòåëüíûì ïåðåãðóçêàì â ïðîöåññå overloads during operation. Wire is
îðãàíè÷åñêèì ëàêîì ýêñïëóàòàöèè. Ïðîâîä óñòîé÷èâ ê resistant to mechanical loads
âîçäåéñòâèþ ìåõàíè÷åñêèõ íàãðóçîê â during manufacturing and
ïðîöåññå èçãîòîâëåíèÿ è ýêñïëóàòàöèè operation of the equipment
îáîðóäîâàíèÿ
7
ÎÁÌÎÒÎ×ÍÛÅ ÏÐÎÂÎÄÀ WINDING WIRES
ñ ýìàëåâî-ñòåêëîâîëîêíèñòîé èçîëÿöèåé with enamel-glass-fiber insulation
ÏÝÒÑËÄ
1. Êðóãëàÿ èëè ïðÿìîóãîëüíàÿ 1. Round or rectangular copper wire.
ìåäíàÿ ïðîâîëîêà. 2. Insulation - polyesterimide enamel.
2. Èçîëÿöèÿ èç ïîëèýôèðèìèäíîãî ëàêà. 3. Insulation - two-ply of polyester-
3. Èçîëÿöèÿ èç äâóõ ñëîåâ fiber with shimming and impregnation
ñòåêëîïîëèýôèðíûõ íèòåé, of electroinsulating glyptal lacquer.
ñ ïîäêëåéêîé è ïðîïèòêîé
ýëåêòðîèçîëÿöèîííûì ãëèôòàëåâûì ëàêîì.
ÏÝÒÑÄ
1. Êðóãëàÿ èëè ïðÿìîóãîëüíàÿ ìåäíàÿ ïðîâîëîêà. 1. Round or rectangular copper wire.
2. Èçîëÿöèÿ èç ïîëèýôèðèìèäíîãî ëàêà. 2. Insulation - polyesterimide enamel.
3. Èçîëÿöèÿ èç äâóõ ñëîåâ ñòåêëÿííûõ íèòåé, 3. Insulation - two-ply of glass-fiber
ñ ïîäêëåéêîé è ïðîïèòêîé ýëåêòðîèçîëÿöèîííûì with shimming and impregnation
ãëèôòàëåâûì ëàêîì of electroinsulating glyptal lacquer.
Ìàðêà Òåìïåðàòóðíûé Ðàçìåð, Ýëåìåíòû êîíñòðóêöèè Îáëàñòü ïðèìåíåíèÿ
è ñòàíäàðò èíäåêñ, °Ñ ìì
Type and Thermal Size, Elements of design Application
standard index, °Ñ mm
ÏÝÒÂÑÄ 155 ∅0,85-2,50 ìåäíàÿ ïðîâîëîêà, copper wire, Ïðîâîä ïðèìåíÿåòñÿ äëÿ èçãîòîâëåíèÿ Wire is used for the production of
ÒÓ 16.Ê71-020-96 "à" 0,80-3,55 èçîëÿöèÿ èç insulation - polyester îáìîòîê òåìïåðàòóðíîãî êëàññà "F": class "F" windings: traction motors
"b" 2,00-10,00 ïîëèýôèðíîãî ëàêà, enamel, òÿãîâûõ äâèãàòåëåé è òðàíñôîðìàòîðîâ. and transformers. Good electrical
èçîëÿöèÿ èç äâóõ insulation - two-ply Âûñîêèå ýëåêòðè÷åñêèå ñâîéñòâà ïðîâîäà properties of wire provide high
ñëîåâ ñòåêëÿííûõ of glass-fiber with îáåñïå÷èâàþò âûñîêóþ ñòåïåíü degree of reliability of the
íèòåé, ñ ïîäêëåéêîé shimming and íàäåæíîñòè îáîðóäîâàíèÿ è ïîçâîëÿþò equipment and make it possible to
è ïðîïèòêîé impregnation of èñïîëüçîâàòü ïðîâîä â îáìîòêàõ use wires in windings of high-
ýëåêòðî- electroinsulating âûñîêîâîëüòíûõ ýëåêòðè÷åñêèõ ìàøèí, voltage electric machines subject to
èçîëÿöèîííûì glyptal lacquer ïîäâåðæåííûõ äëèòåëüíûì ïåðåãðóçêàì â long-term overloads during
ãëèôòàëåâûì ëàêîì ïðîöåññå ýêñïëóàòàöèè operation
ÏÝÒÂÑÄÒ 155 1,32õ5,60 ìåäíàÿ ïðîâîëîêà, copper wire,
ÒÓ 16.Ê71-020-96 3,55õ7,10 óòîíåííàÿ èçîëÿöèÿ thinned insulation -
4,00õ5,60 èç ïîëèýôèðíîãî polyester enamel,
ëàêà, thinned insulation -
óòîíåííàÿ èçîëÿöèÿ two-ply of glass-
èç äâóõ ñëîåâ fiber with shimming
ñòåêëÿííûõ íèòåé, and impregnation of
ñ ïîäêëåéêîé è electroinsulating
ïðîïèòêîé glyptal lacquer
ýëåêòðîèçîëÿ-
öèîííûì ãëèôòàëå-
âûì ëàêîì
ÏÝÒÂÑÄÒ-1 155 "à" 0,90-4,50 ìåäíàÿ ïðîâîëîêà, copper wire, Òàê æå, êàê ÏÝÒÂÑÄÒ, íî óëó÷øåííûå The same as ÏÝÒÂÑÄÒ, but the
ÒÓ 16.Ê09-123-2002, "b" 2,12-11,20 óòîíåííàÿ èçîëÿöèÿ thinned insulation - ýëåêòðè÷åñêèå ñâîéñòâà è ëó÷øàÿ winding will have better electric
ÒÒ èç ïîëèýôèðíîãî polyester enamel, ñîâìåñòèìîñòü ñ ïðîïèòî÷íûì ñîñòàâîì characteristics and compatibility
ëàêà, thinned insulation - with impregnating compaunds
óòîíåííàÿ èçîëÿöèÿ two-ply of glass-
èç äâóõ ñëîåâ fiber with shimming
ñòåêëÿííûõ íèòåé, and impregnation of
ñ ïîäêëåéêîé è electroinsulating
ïðîïèòêîé epoxy lacquer
ýëåêòðîèçîëÿ-
öèîííûì
ýïîêñèäíûì ëàêîì
ÏÝÒÂÑËÄÒ 155 1,32õ5,60 ìåäíàÿ ïðîâîëîêà, copper wire, Ïðîâîä ïðèìåíÿåòñÿ äëÿ èçãîòîâëåíèÿ Wire is used for the production of
ÒÓ 16.Ê71-020-96 3,55õ7,10 óòîíåííàÿ èçîëÿöèÿ thinned insulation - îáìîòîê òåìïåðàòóðíîãî êëàññà "F": class "F" windings: traction motors
4,00õ5,60 èç ïîëèýôèðíîãî polyester enamel, òÿãîâûõ äâèãàòåëåé è òðàíñôîðìàòîðîâ. and transformers. Good electrical
ëàêà, thinned insulation - Âûñîêèå ýëåêòðè÷åñêèå ñâîéñòâà ïðîâîäà properties of wire provide high
óòîíåííàÿ èçîëÿöèÿ two-ply of polyester- îáåñïå÷èâàþò âûñîêóþ ñòåïåíü degree of reliability of the
èç äâóõ ñëîåâ fiber with shimming íàäåæíîñòè îáîðóäîâàíèÿ è ïîçâîëÿþò equipment and make it possible to
ñòåêëîïîëèýôèðíûõ and impregnation of èñïîëüçîâàòü ïðîâîä â îáìîòêàõ use wires in windings of high-
íèòåé, ñ ïîäêëåéêîé electroinsulating âûñîêîâîëüòíûõ ýëåêòðè÷åñêèõ ìàøèí, voltage electric machines subject to
è ïðîïèòêîé glyptal lacquer ïîäâåðæåííûõ äëèòåëüíûì ïåðåãðóçêàì â long-term overloads during
ýëåêòðî- ïðîöåññå ýêñïëóàòàöèè. Ïðîâîä óñòîé÷èâ ê operation. Wire is resistant to
èçîëÿöèîííûì âîçäåéñòâèþ ìåõàíè÷åñêèõ íàãðóçîê â mechanical loads during
ãëèôòàëåâûì ëàêîì ïðîöåññå èçãîòîâëåíèÿ è ýêñïëóàòàöèè manufacturing and operation of the
îáîðóäîâàíèÿ equipment
8
Íîìåíêëàòóðíûé êàòàëîã. ×àñòü 4.
Ìàðêà Òåìïåðàòóðíûé Ðàçìåð, Ýëåìåíòû êîíñòðóêöèè Îáëàñòü ïðèìåíåíèÿ
è ñòàíäàðò èíäåêñ, °Ñ ìì
Type and Thermal Size, Elements of design Application
standard index, °Ñ mm
ÏÝÒÂÑËÄ 155 ∅0,85-2,50 ìåäíàÿ ïðîâîëîêà, copper wire, Òàê æå, êàê ÏÝÒÂÑËÄÒ The same as ÏÝÒÂÑËÄÒ
ÒÓ 16.Ê71-020-96 "à" 0,80-3,55 èçîëÿöèÿ èç ïîëè- insulation - polyester
"b" 2,00-10,00 ýôèðíîãî ëàêà, enamel,
èçîëÿöèÿ èç äâóõ insulation - two-ply
ñëîåâ ñòåêëîïîëè- of polyester-fiber
ýôèðíûõ íèòåé, ñ with shimming and
ïîäêëåéêîé è impregnation of
ïðîïèòêîé ýëåêòðî- electroinsulating
èçîëÿöèîííûì glyptal lacquer
ãëèôòàëåâûì ëàêîì
ÏÝÒÑÄ 180 ∅0,85-2,50 ìåäíàÿ ïðîâîëîêà, copper wire, Ïðîâîä ïðèìåíÿåòñÿ äëÿ èçãîòîâëåíèÿ Wire is used for the production of
ÒÓ 16.Ê71-020-96 "à" 0,80-3,55 èçîëÿöèÿ èç insulation - òåìïåðàòóðíîãî êëàññà "Í": îáìîòîê class "H" windings: high-voltage
"b" 2,00-9,00 ïîëèýôèðèìèäíîãî polyesterimide âûñîêîâîëüòíûõ ýëåêòðè÷åñêèõ ìàøèí è electric machines and
ëàêà, enamel, òðàíñôîðìàòîðîâ. Âûñîêèå ýëåêòðè÷åñêèå transformers.
èçîëÿöèÿ èç äâóõ insulation - two-ply ñâîéñòâà ïðîâîäà îáåñïå÷èâàþò âûñîêóþ Good electrical properties of wire
ñëîåâ ñòåêëÿííûõ of glass-fiber with ñòåïåíü íàäåæíîñòè îáîðóäîâàíèÿ è provide high degree of reliability of
íèòåé, ñ ïîäêëåéêîé shimming and ïîçâîëÿþò èñïîëüçîâàòü ïðîâîä â the equipment and make it
è ïðîïèòêîé impregnation of îáìîòêàõ îáîðóäîâàíèÿ, ïîäâåðãàåìîãî possible to use wires in windings
ýëåêòðî- electroinsulating äëèòåëüíûì ïåðåãðóçêàì â ïðîöåññå of high-voltage electric machines
èçîëÿöèîííûì glyptal lacquer ýêñïëóàòàöèè subject to long-term overloads
ãëèôòàëåâûì ëàêîì during operation
ÏÝÒÑËÄ 180 ∅0,85-2,50 ìåäíàÿ ïðîâîëîêà, copper wire, Ïðîâîä ïðèìåíÿåòñÿ äëÿ èçãîòîâëåíèÿ Wire is used for the production of
ÒÓ 16.Ê71-020-96 "à" 0,80-3,55 èçîëÿöèÿ èç insulation - òåìïåðàòóðíîãî êëàññà "Í": îáìîòîê class "H" windings: high-voltage
"b" 2,00-9,50 ïîëèýôèðèìèäíîãî polyesterimide âûñîêîâîëüòíûõ ýëåêòðè÷åñêèõ ìàøèí è electric machines and
ëàêà, enamel, òðàíñôîðìàòîðîâ. Âûñîêèå ýëåêòðè÷åñêèå transformers. Good electrical
èçîëÿöèÿ èç äâóõ insulation - two-ply ñâîéñòâà ïðîâîäà îáåñïå÷èâàþò âûñîêóþ properties of wire provide high
ñëîåâ ñòåêëî- of polyester-fiber ñòåïåíü íàäåæíîñòè îáîðóäîâàíèÿ è degree of reliability of the
ïîëèýôèðíûõ with shimming and ïîçâîëÿþò èñïîëüçîâàòü ïðîâîä â equipment and make it possible to
íèòåé, impregnation of îáìîòêàõ îáîðóäîâàíèÿ ïîäâåðãàåìîãî use wires in windings of high-
ñ ïîäêëåéêîé è electroinsulating äëèòåëüíûì ïåðåãðóçêàì â ïðîöåññå voltage electric machines subject
ïðîïèòêîé ýëåêòðî- glyptal lacquer ýêñïëóàòàöèè. Ïðîâîä óñòîé÷èâ ê to long-term overloads during
èçîëÿöèîííûì âîçäåéñòâèþ ìåõàíè÷åñêèõ íàãðóçîê â operation. Wire is resistant to
ãëèôòàëåâûì ëàêîì ïðîöåññå èçãîòîâëåíèÿ è ýêñïëóàòàöèè mechanical loads during
îáîðóäîâàíèÿ manufacturing and operation of the
equipment
ÏÝÒÑÄÒ-1-180 180 ∅0,85-3,00 ìåäíàÿ ïðîâîëîêà, copper wire, Ïðîâîä ïðèìåíÿåòñÿ äëÿ èçãîòîâëåíèÿ Wire is used for the production of
ÒÓ 16.Ê09-154-2005 "à" 0,90-3,55 èçîëÿöèÿ èç insulation - îáìîòîê òåìïåðàòóðíîãî êëàññà "Í": class "H" windings: high-voltage
"b" 2,12-9,00 ïîëèýôèðèìèäíîãî polyesterimide ýëåêòðè÷åñêèõ ìàøèí, òÿãîâûõ äâèãàòåëåé electric machines and
ëàêà, enamel, è òðàíñôîðìàòîðîâ. transformers.
óòîíåííàÿ èçîëÿöèÿ thinned insulation - Âûñîêèå ýëåêòðè÷åñêèå ñâîéñòâà ïðîâîäà Good electrical properties of wire
èç äâóõ ñëîåâ two-ply of glass- îáåñïå÷èâàþò âûñîêóþ ñòåïåíü provide high degree of reliability of
ñòåêëÿííûõ íèòåé ñ fiber with shimming íàäåæíîñòè îáîðóäîâàíèÿ è ïîçâîëÿþò the equipment and make it
ïîäêëåéêîé è and impregnation of èñïîëüçîâàòü ïðîâîä â îáìîòêàõ possible to use wires in windings
ïðîïèòêîé ýëåêòðî- electroinsulating âûñîêîâîëüòíûõ ýëåêòðè÷åñêèõ ìàøèí, of high-voltage electric machines
èçîëÿöèîííûì epoxy lacquer ïîäâåðæåííûõ äëèòåëüíûì ïåðåãðóçêàì â subject to long-term overloads
ýïîêñèäíûì ëàêîì ïðîöåññå ýêñïëóàòàöèè during operation
ÏÝÒÑÄÊÒ 200 ∅0,85-3,00 ìåäíàÿ ïðîâîëîêà, copper wire, Ïðîâîä ïðèìåíÿåòñÿ äëÿ èçãîòîâëåíèÿ Wire is used for the production of
ÒÓ 16.Ê09-154-2005 "à" 0,90-3,55 èçîëÿöèÿ èç insulation - îáìîòîê òåìïåðàòóðíîãî êëàññà 200: class 200 windings: high-voltage
"b" 2,12-9,00 ïîëèýôèðèìèäíîãî polyesterimide ýëåêòðè÷åñêèõ ìàøèí, òÿãîâûõ äâèãàòåëåé electric machines and
ëàêà, enamel, è òðàíñôîðìàòîðîâ. transformers.
óòîíåííàÿ èçîëÿöèÿ thinned insulation - Âûñîêèå ýëåêòðè÷åñêèå ñâîéñòâà ïðîâîäà Good electrical properties of wire
èç äâóõ ñëîåâ two-ply of glass- îáåñïå÷èâàþò âûñîêóþ ñòåïåíü provide high degree of reliability of
ñòåêëÿííûõ íèòåé ñ fiber with shimming íàäåæíîñòè îáîðóäîâàíèÿ è ïîçâîëÿþò the equipment and make it
ïîäêëåéêîé è and impregnation of èñïîëüçîâàòü ïðîâîä â îáìîòêàõ possible to use wires in windings
ïðîïèòêîé silicone lacquer âûñîêîâîëüòíûõ ýëåêòðè÷åñêèõ ìàøèí, of high-voltage electric machines
êðåìíèéîðãàíè- ïîäâåðæåííûõ äëèòåëüíûì ïåðåãðóçêàì â subject to long-term overloads
÷åñêèì ëàêîì ïðîöåññå ýêñïëóàòàöèè during operation
ÏÝÒÑËÄÊÒ 200 ∅0,85-3,00 ìåäíàÿ ïðîâîëîêà, copper wire, Ïðîâîä ïðèìåíÿåòñÿ äëÿ èçãîòîâëåíèÿ Wire is used for the production of
ÒÓ 16.Ê09-154-2005 "à" 0,90-3,55 èçîëÿöèÿ èç insulation - îáìîòîê òåìïåðàòóðíîãî êëàññà 200: class 200 windings: high-voltage
"b" 2,12-9,00 ïîëèýôèðèìèäíîãî polyesterimide ýëåêòðè÷åñêèõ ìàøèí, òÿãîâûõ äâèãàòåëåé electric machines and
ëàêà, enamel, è òðàíñôîðìàòîðîâ. transformers.
óòîíåííàÿ èçîëÿöèÿ thinned insulation - Âûñîêèå ýëåêòðè÷åñêèå ñâîéñòâà ïðîâîäà Good electrical properties of wire
èç äâóõ ñëîåâ two-ply of glass- îáåñïå÷èâàþò âûñîêóþ ñòåïåíü provide high degree of reliability of
ñòåêëîïîëèýôèðíûõ fiber with shimming íàäåæíîñòè îáîðóäîâàíèÿ è ïîçâîëÿþò the equipment and make it
íèòåé ñ ïîäêëåéêîé and impregnation of èñïîëüçîâàòü ïðîâîä â îáìîòêàõ possible to use wires in windings
è ïðîïèòêîé electroinsulating âûñîêîâîëüòíûõ ýëåêòðè÷åñêèõ ìàøèí, of high-voltage electric machines
ýëåêòðîèçîëÿöèîí- epoxy lacquer ïîäâåðæåííûõ äëèòåëüíûì ïåðåãðóçêàì â subject to long-term overloads
íûì ýïîêñèäíûì ïðîöåññå ýêñïëóàòàöèè during operation
ëàêîì
9
ÎÁÌÎÒÎ×ÍÛÅ ÏÐÎÂÎÄÀ WINDING WIRES
ñ ïëåíî÷íîé èçîëÿöèåé with film insulation
ÏÏÈÏÊ-1
1. Ïðÿìîóãîëüíàÿ ìåäíàÿ ïðîâîëîêà. 1. Rectangular copper wire.
2. Èçîëÿöèÿ èç ïîëèèìèäíî- 2. Insulation - of
ôòîðîïëàñòîâîé ïëåíêè. polyimide-fluoroplastic film.
Ìàðêà Òåìïåðàòóðíûé Ðàçìåð, Ýëåìåíòû êîíñòðóêöèè Îáëàñòü ïðèìåíåíèÿ
è ñòàíäàðò èíäåêñ, °Ñ ìì
Type and Thermal Size, Elements of design Application
standard index, °Ñ mm
ÏÏÈ-Ó 200 ∅1,06-3,15 ìåäíàÿ ïðîâîëîêà, copper wire, Ïðîâîä ïðåäíàçíà÷åí äëÿ îáìîòêè Wires are intended for winding of
ÒÓ 16-705-159-80 èçîëÿöèÿ èç ïîëèèìèäíî- insulation - of ñòàòîðîâ ïîãðóæíûõ stators of submersible oil filled
ôòîðîïëàñòîâîé polyimide-fluoroplastic ìàñëîíàïîëíåííûõ electric motors. Excellent electric
ïëåíêè film ýëåêòðîäâèãàòåëåé. Ïðåâîñõîäíûå properties of wires provide high
ýëåêòðè÷åñêèå ñâîéñòâà ïðîâîäà reliability of the equipment subject
îáåñïå÷èâàþò âûñîêóþ ñòåïåíü to overloads. Wires have excellent
íàäåæíîñòè îáîðóäîâàíèÿ, mechanical properties and
ïîäâåðãàþùåãîñÿ ïåðåãðóçêàì. elasticity
Ïðîâîä îáëàäàåò îòëè÷íûìè
ìåõàíè÷åñêèìè ñâîéñòâàìè è
ýëàñòè÷íîñòüþ
ÏÏÈÏÊ-Ò 200 "à" 1,40-4,00 ìåäíàÿ ïðîâîëîêà, copper wire, Ïðîâîä ïðèìåíÿåòñÿ äëÿ Wires are intended for production
ÒÓ 16.Ê71-202-93 "b" 5,30-11,20 èçîëÿöèÿ èç ïîëèèìèäíî- insulation - polyimide- èçãîòîâëåíèÿ ñòàòîðíûõ îáìîòîê of stator windings of thermal class
(9-30 mm2) ôòîðîïëàñòîâîé ïëåíêè fluoroplastic ýëåêòðè÷åñêèõ ìàøèí "C" electric machines: traction
(íîìèíàëüíàÿ òîëùèíà film (nominal òåìïåðàòóðíîãî êëàññà "C": òÿãîâûå engines of super-size tippers,
èçîëÿöèè 0,16 ìì) thickness of äâèãàòåëè áîëüøåãðóçíûõ locomotives, rolling mills and
insulation 0,16 mm) ñàìîñâàëîâ, ìàãèñòðàëüíûõ drilling equipment. Due to high
ýëåêòðîâîçîâ, òåïëîâîçîâ, electric and mechanical properties
ÏÏÈÏÊ-1 200 "à" 1,40-4,00 ìåäíàÿ ïðîâîëîêà, copper wire, ýëåêòðîáóðîâ è ïðîêàòíûõ ñòàíîâ. wires provide high reliability of
ÒÓ 16.Ê71-202-93 "b" 5,30-11,20 èçîëÿöèÿ èç ïîëèèìèäíî- insulation - polyimide- Áëàãîäàðÿ âûñîêèì ýëåêòðè÷åñêèì units subject to severe operation
(9-30 mm2) ôòîðîïëàñòîâîé ïëåíêè fluoroplastic è ìåõàíè÷åñêèì õàðàêòåðèñòèêàì conditions: long terms overloads
(íîìèíàëüíàÿ òîëùèíà film (nominal thickness ïðîâîä îáåñïå÷èâàåò âûñîêóþ and vibration.
èçîëÿöèè 0,23 ìì) of insulation ñòåïåíü íàäåæíîñòè èçäåëèé, Wires allow varnish impregnation
0,23 mm) ðàáîòàþùèõ â êðàéíå òÿæåëûõ and compounding of the finished
óñëîâèÿõ ýêñïëóàòàöèè: winding
ÏÏÈÏÊ-2 200 "à" 1,40-4,00 ìåäíàÿ ïðîâîëîêà, copper wire,
çíà÷èòåëüíûå äîëãîâðåìåííûå
ÒÓ 16.Ê71-202-93 "b" 5,30-11,20 èçîëÿöèÿ èç ïîëèèìèäíî- insulation - polyimide-
ïåðåãðóçêè è âèáðàöèÿ.
(9-30 mm2) ôòîðîïëàñòîâîé ïëåíêè fluoroplastic
Ïðîâîäà äîïóñêàþò ïðîïèòêó
(íîìèíàëüíàÿ òîëùèíà film (nominal
ëàêàìè è êîìïàóíäèðîâàíèå
èçîëÿöèè 0,30 ìì) thickness of
ãîòîâîé îáìîòêè
insulation 0,30 mm)
ÏÏÈÏÊ-3 200 "à" 1,40-4,00 ìåäíàÿ ïðîâîëîêà, copper wire,
ÒÓ 16-705.035-82 "b" 5,30-11,20 èçîëÿöèÿ èç ïîëèèìèäíî- insulation -polyimide-
(9-30 mm2) ôòîðîïëàñòîâîé fluoroplastic
ïëåíêè (íîìèíàëüíàÿ film (nominal
òîëùèíà èçîëÿöèè thickness of
0,35 ìì) insulation 0,35 mm)
ÎÁÌÎÒÎ×ÍÛÅ ÏÐÎÂÎÄÀ WINDING WIRES
ñ áóìàæíîé èçîëÿöèåé with paper insulation
ÏÁ
1. Ìåäíàÿ ïðîâîëîêà. 1. Ñopper wire.
2. Èçîëÿöèÿ èç ëåíò êàáåëüíîé áóìàãè. 2. Insulation - tapes of cable paper.
Ìàðêà Òåìïåðàòóðíûé Ðàçìåð, Ýëåìåíòû êîíñòðóêöèè Îáëàñòü ïðèìåíåíèÿ
è ñòàíäàðò èíäåêñ, °Ñ ìì
Type and Thermal Size, Elements of design Application
standard index, °Ñ mm
ÀÏÁ 105 ∅1,70-8,00 àëþìèíèåâàÿ aluminium wire, Ïðîâîä ïðèìåíÿåòñÿ äëÿ èçãîòîâëåíèÿ Wires are intended for windings of
ÒÓ 16.Ê71-108-94 "à" 1,00-5,60 ïðîâîëîêà, insulation - tape of îáìîòîê òåìïåðàòóðíîãî êëàññà "À": thermal class "A": electric motors,
"b" 3,00-19,50 èçîëÿöèÿ èç ëåíò cable paper ýëåêòðè÷åñêèõ ìàøèí, àïïàðàòîâ è apparatus and transformers,
êàáåëüíîé áóìàãè òðàíñôîðìàòîðîâ, ðàáîòàþùèõ â ñðåäå operating in the environment of
ýëåêòðîèçîëÿöèîííîãî ìàñëà insulating oil
ÏÁ 105 ∅1,70-8,00 ìåäíàÿ ïðîâîëîêà, copper wire,
ÒÓ 16.Ê71-108-94 "à" 1,00-5,60 èçîëÿöèÿ èç ëåíò insulation - tape of
"b" 3,00-19,50 êàáåëüíîé áóìàãè cable paper
ÏÏÀ 180 "à" 1,40-5,00 ìåäíàÿ ïðîâîëîêà, copper wire, Ïðîâîä ïðèìåíÿåòñÿ äëÿ èçãîòîâëåíèÿ Intended for windings of electric
ÒÓ 16.Ê09-151-05 "b" 3,35-12,50 èçîëÿöèÿ èç insulation of îáìîòîê ýëåêòðè÷åñêèõ ìàøèí, machines, apparatus and
ýëåêòðîèçîëÿöèîííîé “Nomex” paper àïïàðàòîâ è òðàíñôîðìàòîðîâ transformers of thermal class “H”
àðàìèäíîé áóìàãè Òåìïåðàòóðíûé êëàññ "Í"
"Íîìåêñ"
10