Table Of ContentSRK-Z
1. INVERTER WALL MOUNTED TYPE
ROOM AIR-CONDITIONER
( S p l it s y s t e m , A ir t o a i r )
heat pump type
1.1 SRK20ZD-S SRK25ZC-S
SRK25ZD-S SRK35ZC-S
SRK35ZD-S SRK50ZC-S
SRK50ZD-S .............................................................. 2
1.2 SRK63ZE-S
SRK71ZE-S............................................................... 74
1
CONTENTS
1.1.1 GENERAL INFORMATION....................................................................... 3
(1) Specific features.................................................................................... 3
(2) How to read the model name................................................................ 3
1.1.2 SELECTION DATA.................................................................................... 4
(1) Specifications ........................................................................................ 4
(2) Range of usage & limitations...............................................................11
(3) Exterior dimensions..............................................................................11
(4) Piping system ........................................................................................14
(5) Selection chart.......................................................................................15
1.1.3 ELECTRICAL DATA .................................................................................16
(1) Electrical wiring.....................................................................................16
1.1.4 OUTLINE OF OPERATION CONTROL BY MICROCOMPUTER ............18
(1) Operation control function by remote control switch........................18
(2) Unit ON/OFF button...............................................................................19
(3) Power blackout auto restart function ..................................................19
(4) Flap control............................................................................................20
(5) Comfortable timer setting.....................................................................20
(6) Outline of heating operation ................................................................21
(7) Outline of cooling operation ................................................................23
(8) Outline of dehumidifying operation.....................................................24
(9) Outline of automatic operation ............................................................26
(10) Economical operation...........................................................................26
(11) Protective control function...................................................................26
1.1.5 APPLICATION DATA ................................................................................32
(1) Selection of location for installation....................................................33
(2) Installation of indoor unit .....................................................................34
(3) Installation of outdoor unit...................................................................36
(4) Refrigerant piping .................................................................................36
(5) Test run ..................................................................................................38
(6) Precautions for wireless remote controller installation and
operation ................................................................................................39
1.1.6 MAINTENANCE DATA..............................................................................40
(1) Troubleshooting procedures for electrical equipment ......................40
(2) Servicing ................................................................................................58
1.1.7 REFRIGERANT PIPING INSTALLATION/SERVICING MANUAL
FOR AIR CONDITIONERS USING R410A ..............................................59
(1) Outline ....................................................................................................59
(2) Refrigerant piping installation .............................................................60
(3) Installation, removal and servicing......................................................66
(4) Refrigerant recovery .............................................................................71
2
1.1.1 GENERAL INFORMATION
(1) Specific features
The “Mitsubishi Daiya” room air-conditioner: SRK series are of split and wall mounted type and the unit consists of indoor unit and
outdoor unit with refrigerant precharged in factory. The indoor unit is composed of room air cooling or heating equipment with opera-
tion control switch and the outdoor unit is composed of condensing unit with compressor.
(a) Inverter (Frequency converter) for multi-steps power control
¡Heating/Cooling
The rotational speed of a compressor is changed in step in relation to varying load, interlocked with the indoor and outdoor unit
fans controlled to change frequency, thus controlling the capacity.
¡Allowing quick heating/cooling operation during start-up period. Constant room temperature by fine-tuned control after the
unit has stabilized.
(b) Fuzzy control
¡Fuzzy control calculates the amount of variation in the difference between the return air temperature and the setting temperature
in compliance with the fuzzy rules in order to control the air capacity and the inverter frequency.
(c) Remote control flap
The flap can be automatically controlled by operating wireless remote control.
¡Air scroll (AUTO): Flap operation is automatically control.
¡Swing: This will swing the flap up and down.
¡Memory flap: Once the flap position is set, the unit memorizes the position and continues to operate at the same position from
the next time.
(d) Self diagnosis function
¡We are constantly trying to do better service to our customers by installing such judges that show abnormality of operation as
follows.
RUN light TIMER light Outdoor (LED)
1 time flash Heat exchanger sensor error 1 time flash OFF Outdoor temperature sensor error
TIMER light RUN light Outdoor heat exchanger liquid
2 time flash Room temperature sensor error 2 time flash OFF
ON keeps flashing pipe sensor error
6 time flash Indoor fan motor error 4 time flash OFF Discharge pipe sensor error
1 time flash 1 time flash Current cut
2 time flash 2 time flash Trouble of outdoor unit
RUN light
3 time flash 3 time flash Over current
ON
5 time flash 5 time flash Over heat of compressor
6 time flash 6 time flash Error of signal transmission
7 time flash ON Outdoor fan motor error
(20, 25, 35 type only)
RUN light
2 time flash 7 time flash Rotor lock
2 time flash
(2) How to read the model name
Example : SR K 35 Z D - S
R410A models
Series No.
Inverter type
Product capacity
Wall mounted type
Split type room air-conditioner
3
1.1.2 SELECTION DATA
(1) Specifications
Model SRK20ZD-S (Indoor unit)
SRC20ZD-S (Outdoor unit) (220/230/240V)
Model
SRK20ZD-S SRC20ZD-S
Item
Cooling capacity(1) W 2000 (500~2800)
Heating capacity(1) W 2700 (500~4600)
Power source 1 Phase, 220-240V, 50Hz
Cooling input kW 0.44 (0.1~0.91)
Running current (Cooling) A 2.4/2.3/2.2
(1)ata HRueantniningg i ncpuurrtent (Heating) kAW 0.632. 0(0/2.0.99/~21.8.27)
n d Inrush current A 3.0/2.9/2.8
atio COP Cooling: 4.55 Heating: 4.35
per Cooling Sound level Hi 36, Me 29, Lo 21 44
O Power level 52 58
Noise level dB
Sound level Hi 38, Me 32, Lo 25 47
Heating
Power level 54 61
Exterior dimensions
Height × Width × Depth mm 250 × 815 × 249 540 × 720 × 290
Color Cool white Stucco white
Net weight kg 9.0 32
Refrigerant equipment
– RM-B5077MD1 (Rotary type) × 1
Compressor type & Q’ty
Motor kW – 0.75
Starting method – Line starting
Heat exchanger Louver fins & inner grooved tubing Straight fins & inner grooved tubing
Refrigerant control Capillary tubes + Electronic expansion valve
Refrigerant(3) kg R410A 0.9 (Pre-Charged up to the piping length of 15m)
Refrigerant oil R 0.35 (MA68)
Deice control Microcomputer control
Air handling equipment
Tangential fan × 1 Propeller fan × 1
Fan type & Q’ty
Motor W 29 24
(Cooling) 7.2 30
Air flow (at High) CMM
(Heating) 8.3 25
Air filter, Q’ty Polypropylene net (washable) × 2 –
Shock & vibration absorber – Cushion rubber (for compressor)
Electric heater – –
Operation control
Wireless-Remote controller –
Operation switch
Room temperature control Microcomputer thermostat –
Pilot lamp RUN (Green), TIMER (Yellow), HI POWER (Green), ECONO (Orange)
Safety equipment Compressor overheat protection, Heating overload protection (High pressure control), Overcurrent protection,
Frost protection, Serial signal error protection, Indoor fan motor error protection, Cooling overload protection
O.D mm (in) Liquid line: φ6.35 (1/4″) Gas line: φ9.52 (3/8″)
nt Connecting method Flare connecting
a
er Attached length of piping Liquid line: 0.47 m
Refrigpiping Insulation Gas line : 0.40 m Necessary (Both sides) –
Drain hose Connectable
Power source cord 2.5 m (3 cores with Earth)
Size × Core number 1.5 mm2 × 4 cores (Including earth cable)
Connection wiring
Connecting method Terminal block (Screw fixing type)
Accessories (included) Mounting kit
Optional parts –
Notes(1) The data are measured at the following conditions.
Item Indoor air temperature Outdoor air temperature
Standards
Operation DB WB DB WB
Cooling 27ºC 19ºC 35ºC 24ºC ISO-T1, JIS C9612
Heating 20ºC – 7ºC 6ºC ISO-T1, JIS C9612
The piping length is 7.5m.
(2) The operation data are applied to the 220/230/240V districts respectively.
(3) The refrigerant quantity to be charged includes the refrigerant in 15 m connecting piping.
(Purging is not required even for the short piping.)
4
Model SRK25ZD-S (Indoor unit)
SRC25ZD-S (Outdoor unit)
(220/230/240V)
Model
SRK25ZD-S SRC25ZD-S
Item
Cooling capacity(1) W 2500 (500~3000)
Heating capacity(1) W 3400 (500~4800)
Power source 1 Phase, 220-240V, 50Hz
Cooling input kW 0.62 (0.1~0.97)
Running current (Cooling) A 3.1/3.0/2.9
(1)ata HRueantniningg i ncpuurrtent (Heating) kAW 0.944. 5(0/4.0.39/~41.1.30)
n d Inrush current A 4.5/4.3/4.1
atio COP Cooling: 4.03 Heating: 3.62
per Cooling Sound level Hi 37, Me 30, Lo 22 44
O Power level 53 58
Noise level dB
Sound level Hi 39, Me 33, Lo 26 47
Heating
Power level 55 61
Exterior dimensions
Height × Width × Depth mm 250 × 815 × 249 540 × 720 × 290
Color Cool white Stucco white
Net weight kg 9.0 32
Refrigerant equipment
– RM-B5077MD1 (Rotary type) × 1
Compressor type & Q’ty
Motor kW – 0.75
Starting method – Line starting
Heat exchanger Louver fins & inner grooved tubing Straight fins & inner grooved tubing
Refrigerant control Capillary tubes + Electronic expansion valve
Refrigerant(3) kg R410A 0.9 (Pre-Charged up to the piping length of 15m)
Refrigerant oil R 0.35 (MA68)
Deice control Microcomputer control
Air handling equipment
Tangential fan × 1 Propeller fan × 1
Fan type & Q’ty
Motor W 29 24
(Cooling) 8.0 30
Air flow (at High) CMM
(Heating) 8.7 25
Air filter, Q’ty Polypropylene net (washable) × 2 –
Shock & vibration absorber – Cushion rubber (for compressor)
Electric heater – –
Operation control
Wireless-Remote controller –
Operation switch
Room temperature control Microcomputer thermostat –
Pilot lamp RUN (Green), TIMER (Yellow), HI POWER (Green), ECONO (Orange)
Safety equipment Compressor overheat protection, Heating overload protection (High pressure control), Overcurrent protection,
Frost protection, Serial signal error protection, Indoor fan motor error protection, Cooling overload protection
O.D mm (in) Liquid line: φ6.35 (1/4″) Gas line: φ9.52 (3/8″)
nt Connecting method Flare connecting
a
er Attached length of piping Liquid line: 0.47 m
Refrigpiping Insulation Gas line : 0.40 m Necessary (Both sides) –
Drain hose Connectable
Power source cord 2.5 m (3 cores with Earth)
Size × Core number 1.5 mm2 × 4 cores (Including earth cable)
Connection wiring
Connecting method Terminal block (Screw fixing type)
Accessories (included) Mounting kit
Optional parts –
Notes(1) The data are measured at the following conditions.
Item Indoor air temperature Outdoor air temperature
Standards
Operation DB WB DB WB
Cooling 27ºC 19ºC 35ºC 24ºC ISO-T1, JIS C9612
Heating 20ºC – 7ºC 6ºC ISO-T1, JIS C9612
The piping length is 7.5m.
(2) The operation data are applied to the 220/230/240V districts respectively.
(3) The refrigerant quantity to be charged includes the refrigerant in 15 m connecting piping.
(Purging is not required even for the short piping.)
5
Model SRK35ZD-S (Indoor unit)
SRC35ZD-S (Outdoor unit)
(220/230/240V)
Model
SRK35ZD-S SRC35ZD-S
Item
Cooling capacity(1) W 3500 (500~3900)
Heating capacity(1) W 4500 (500~5100)
Power source 1 Phase, 220-240V, 50Hz
Cooling input kW 1.09 (0.1~1.22)
Running current (Cooling) A 5.4/5.2/5.0
(1)ata HRueantniningg i ncpuurrtent (Heating) kAW 1.254. 9(0/5.0.79/~51.4.32)
n d Inrush current A 5.9/5.7/5.4
atio COP Cooling: 3.21 Heating: 3.63
er Sound level Hi 41, Me 32, Lo 23 48
p Cooling
O Power level 58 62
Noise level dB
Sound level Hi 45, Me 36, Lo 27 50
Heating
Power level 59 64
Exterior dimensions
Height × Width × Depth mm 250 × 815 × 249 540 × 720 × 290
Color Cool white Stucco white
Net weight kg 9.0 35
Refrigerant equipment
– RM-B5077MD1 [Rotary type] × 1
Compressor type & Q’ty
Motor kW – 0.90
Starting method – Line starting
Heat exchanger Louver fins & inner grooved tubing Straight fins & inner grooved tubing
Refrigerant control Capillary tubes + Electronic expansion valve
Refrigerant(3) kg R410A 1.1 (Pre-Charged up to the piping length of 15m)
Refrigerant oil R 0.35 (MA68)
Deice control Microcomputer control
Air handling equipment
Tangential fan × 1 Propeller fan × 1
Fan type & Q’ty
Motor W 29 24
(Cooling) 8.9 34
Air flow (at High) CMM
(Heating) 10.3 34
Air filter, Q’ty Polypropylene net (washable) × 2 –
Shock & vibration absorber – Cushion rubber (for compressor)
Electric heater – –
Operation control
Wireless-Remote controller –
Operation switch
Room temperature control Microcomputer thermostat –
Pilot lamp RUN (Green), TIMER (Yellow), HI POWER (Green), ECONO (Orange)
Safety equipment Compressor overheat protection, Heating overload protection (High pressure control), Overcurrent protection,
Frost protection, Serial signal error protection, Indoor fan motor error protection, Cooling overload protection
O.D mm (in) Liquid line: φ6.35 (1/4″) Gas line: φ9.52 (3/8″)
nt Connecting method Flare connecting
a
Refrigerpiping AIntstauclahteiodn length of piping LGiqausi dli nlien e: :0 0.4.407 m mNecessary (Both sides) –
Drain hose Connectable
Power source cord 2.5 m (3 cores with Earth)
Size × Core number 1.5 mm2 × 4 cores (Including earth cable)
Connection wiring
Connecting method Terminal block (Screw fixing type)
Accessories (included) Mounting kit
Optional parts –
Notes(1) The data are measured at the following conditions.
Item Indoor air temperature Outdoor air temperature
Standards
Operation DB WB DB WB
Cooling 27ºC 19ºC 35ºC 24ºC ISO-T1, JIS C9612
Heating 20ºC – 7ºC 6ºC ISO-T1, JIS C9612
The piping length is 7.5m.
(2) The operation data are applied to the 220/230/240V districts respectively.
(3) The refrigerant quantity to be charged includes the refrigerant in 15 m connecting piping.
(Purging is not required even for the short piping.)
6
Model SRK50ZD-S (Indoor unit)
SRC50ZD-S (Outdoor unit)
(220/230/240V)
Model
SRK50ZD-S SRC50ZD-S
Item
Cooling capacity(1) W 5000 (600~5300)
Heating capacity(1) W 6300 (600~7900)
Power source 1 Phase, 220-240V, 50Hz
Cooling input kW 1.66 (0.12~2.1)
Running current (Cooling) A 7.6/7.3/7.0
(1)ata HReuantniningg i ncpuurrtent (Heating) kAW 1.996. 0(0/8.1.61/~82.2.71)
n d Inrush current A 9.0/8.6/8.2
atio COP Cooling: 3.01 Heating: 3.21
er Sound level Hi 48, Me 42, Lo 26 48
p Cooling
O Power level 61 61
Noise level dB
Sound level Hi 46, Me 40, Lo 34 49
Heating
Power level 62 64
Exterior dimensions
Height × Width × Depth mm 250 × 815 × 249 640 × 850 × 290
Color Cool white Stucco white
Net weight kg 9.0 43
Refrigerant equipment
– 5CS102XFA [Scroll type] × 1
Compressor type & Q’ty
Motor kW – 1.5
Starting method – Line starting
Heat exchanger Slit fins + Louver fins & inner grooved tubing Straight fins & inner grooved tubing
Refrigerant control Capillary tubes + Electronic expansion valve
Refrigerant(3) kg R410A 1.35 (Pre-Charged up to the piping length of 15m)
Refrigerant oil R 0.36 (RB68A)
Deice control Microcomputer control
Air handling equipment
Tangential fan × 1 Propeller fan × 1
Fan type & Q’ty
Motor W 29 45
(Cooling) 11.5 42
Air flow (at High) CMM
(Heating) 13.0 42
Air filter, Q’ty Polypropylene net (washable) × 2 –
Shock & vibration absorber – Cushion rubber (for compressor)
Electric heater – –
Operation control
Wireless-Remote controller –
Operation switch
Room temperature control Microcomputer thermostat –
Pilot lamp RUN (Green), TIMER (Yellow), HI POWER (Green), ECONO (Orange)
Safety equipment Compressor overheat protection, Heating overload protection (High pressure control), Overcurrent protection,
Frost protection, Serial signal error protection, Indoor fan motor error protection, Cooling overload protection
O.D mm (in) Liquid line: φ6.35 (1/4″) Gas line: φ12.7 (1/2″)
nt Connecting method Flare connecting
a
Refrigerpiping AIntstauclahteiodn length of piping LGiqausi dli nlien e: :0 0.4.407 m mNecessary (Both sides) –
Drain hose Connectable
Power source cord 2.5 m (3 cores with Earth)
Size × Core number 1.5 mm2 × 4 cores (Including earth cable)
Connection wiring
Connecting method Terminal block (Screw fixing type)
Accessories (included) Mounting kit
Optional parts –
Notes(1) The data are measured at the following conditions.
Item Indoor air temperature Outdoor air temperature
Standards
Operation DB WB DB WB
Cooling 27ºC 19ºC 35ºC 24ºC ISO-T1, JIS C9612
Heating 20ºC – 7ºC 6ºC ISO-T1, JIS C9612
The piping length is 7.5m.
(2) The operation data are applied to the 220/230/240V districts respectively.
(3) The refrigerant quantity to be charged includes the refrigerant in 15 m connecting piping.
(Purging is not required even for the short piping.)
If the piping length is longer, when it is 15 to 25m, add 20 g refrigerant per meter.
7
Model SRK25ZC-S (Indoor unit)
SRC25ZC-S (Outdoor unit)
(220/230/240V)
Model
SRK25ZC-S SRC25ZC-S
Item
Cooling capacity(1) W 2500 (500~3000)
Heating capacity(1) W 3400 (500~4800)
Power source 1 Phase, 220-240V, 50Hz
Cooling input kW 0.62 (0.1~0.97)
Running current (Cooling) A 3.1/3.0/2.9
(1)ata HRueantniningg i ncpuurrtent (Heating) kAW 0.944. 5(0/4.0.39/~41.1.30)
n d Inrush current A 4.5/4.3/4.1
atio COP Cooling: 4.03 Heating: 3.62
per Cooling Sound level Hi 37, Me 30, Lo 22 44
O Power level 53 58
Noise level dB
Sound level Hi 39, Me 33, Lo 26 47
Heating
Power level 55 61
Exterior dimensions
Height × Width × Depth mm 250 × 815 × 247 540 × 720 × 290
Color Cool white Stucco white
Net weight kg 9.0 32
Refrigerant equipment
– RM-B5077MD1 (Rotary type) × 1
Compressor type & Q’ty
Motor kW – 0.75
Starting method – Line starting
Heat exchanger Louver fins & inner grooved tubing Straight fins & inner grooved tubing
Refrigerant control Capillary tubes + Electronic expansion valve
Refrigerant(3) kg R410A 0.9 (Pre-Charged up to the piping length of 15m)
Refrigerant oil R 0.35 (MA68)
Deice control Microcomputer control
Air handling equipment
Tangential fan × 1 Propeller fan × 1
Fan type & Q’ty
Motor W 29 24
(Cooling) 8.0 30
Air flow (at High) CMM
(Heating) 8.7 25
Air filter, Q’ty Polypropylene net (washable) × 2 –
Shock & vibration absorber – Cushion rubber (for compressor)
Electric heater – –
Operation control
Wireless-Remote controller –
Operation switch
Room temperature control Microcomputer thermostat –
Pilot lamp RUN (Green), TIMER (Yellow), HI POWER (Green), ECONO (Orange)
Safety equipment Compressor overheat protection, Heating overload protection (High pressure control), Overcurrent protection,
Frost protection, Serial signal error protection, Indoor fan motor error protection, Cooling overload protection
O.D mm (in) Liquid line: φ6.35 (1/4″) Gas line: φ9.52 (3/8″)
nt Connecting method Flare connecting
a
er Attached length of piping Liquid line: 0.47 m
Refrigpiping Insulation Gas line : 0.40 m Necessary (Both sides) –
Drain hose Connectable
Power source cord 2.5 m (3 cores with Earth)
Size × Core number 1.5 mm2 × 4 cores (Including earth cable)
Connection wiring
Connecting method Terminal block (Screw fixing type)
Accessories (included) Mounting kit
Optional parts –
Notes(1) The data are measured at the following conditions.
Item Indoor air temperature Outdoor air temperature
Standards
Operation DB WB DB WB
Cooling 27ºC 19ºC 35ºC 24ºC ISO-T1, JIS C9612
Heating 20ºC – 7ºC 6ºC ISO-T1, JIS C9612
The piping length is 7.5m.
(2) The operation data are applied to the 220/230/240V districts respectively.
(3) The refrigerant quantity to be charged includes the refrigerant in 15 m connecting piping.
(Purging is not required even for the short piping.)
8
Model SRK35ZC-S (Indoor unit)
SRC35ZC-S (Outdoor unit)
(220/230/240V)
Model
SRK35ZC-S SRC35ZC-S
Item
Cooling capacity(1) W 3500 (500~3900)
Heating capacity(1) W 4500 (500~5100)
Power source 1 Phase, 220-240V, 50Hz
Cooling input kW 1.09 (0.1~1.22)
Running current (Cooling) A 5.4/5.2/5.0
(1)ata HRueantniningg i ncpuurrtent (Heating) kAW 1.254. 9(0/5.0.79/~51.4.32)
n d Inrush current A 5.9/5.7/5.4
atio COP Cooling: 3.21 Heating: 3.63
er Sound level Hi 41, Me 32, Lo 23 48
p Cooling
O Power level 58 62
Noise level dB
Sound level Hi 45, Me 36, Lo 27 50
Heating
Power level 59 64
Exterior dimensions
Height × Width × Depth mm 250 × 815 × 247 540 × 720 × 290
Color Cool white Stucco white
Net weight kg 9.0 35
Refrigerant equipment
– RM-B5077MD1 [Rotary type] × 1
Compressor type & Q’ty
Motor kW – 0.90
Starting method – Line starting
Heat exchanger Louver fins & inner grooved tubing Straight fins & inner grooved tubing
Refrigerant control Capillary tubes + Electronic expansion valve
Refrigerant(3) kg R410A 1.1 (Pre-Charged up to the piping length of 15m)
Refrigerant oil R 0.35 (MA68)
Deice control Microcomputer control
Air handling equipment
Tangential fan × 1 Propeller fan × 1
Fan type & Q’ty
Motor W 29 24
(Cooling) 8.9 34
Air flow (at High) CMM
(Heating) 10.3 34
Air filter, Q’ty Polypropylene net (washable) × 2 –
Shock & vibration absorber – Cushion rubber (for compressor)
Electric heater – –
Operation control
Wireless-Remote controller –
Operation switch
Room temperature control Microcomputer thermostat –
Pilot lamp RUN (Green), TIMER (Yellow), HI POWER (Green), ECONO (Orange)
Safety equipment Compressor overheat protection, Heating overload protection (High pressure control), Overcurrent protection,
Frost protection, Serial signal error protection, Indoor fan motor error protection, Cooling overload protection
O.D mm (in) Liquid line: φ6.35 (1/4″) Gas line: φ9.52 (3/8″)
nt Connecting method Flare connecting
a
Refrigerpiping AIntstauclahteiodn length of piping LGiqausi dli nlien e: :0 0.4.407 m mNecessary (Both sides) –
Drain hose Connectable
Power source cord 2.5 m (3 cores with Earth)
Size × Core number 1.5 mm2 × 4 cores (Including earth cable)
Connection wiring
Connecting method Terminal block (Screw fixing type)
Accessories (included) Mounting kit
Optional parts –
Notes(1) The data are measured at the following conditions.
Item Indoor air temperature Outdoor air temperature
Standards
Operation DB WB DB WB
Cooling 27ºC 19ºC 35ºC 24ºC ISO-T1, JIS C9612
Heating 20ºC – 7ºC 6ºC ISO-T1, JIS C9612
The piping length is 7.5m.
(2) The operation data are applied to the 220/230/240V districts respectively.
(3) The refrigerant quantity to be charged includes the refrigerant in 15 m connecting piping.
(Purging is not required even for the short piping.)
9
Model SRK50ZC-S (Indoor unit)
SRC50ZC-S (Outdoor unit)
(220/230/240V)
Model
SRK50ZC-S SRC50ZC-S
Item
Cooling capacity(1) W 5000 (600~5300)
Heating capacity(1) W 6300 (600~7900)
Power source 1 Phase, 220-240V, 50Hz
Cooling input kW 1.66 (0.12~2.1)
Running current (Cooling) A 7.6/7.3/7.0
(1)ata HReuantniningg i ncpuurrtent (Heating) kAW 1.996. 0(0/8.1.61/~82.2.71)
n d Inrush current A 9.0/8.6/8.2
atio COP Cooling: 3.01 Heating: 3.21
er Sound level Hi 48, Me 42, Lo 26 48
p Cooling
O Power level 61 61
Noise level dB
Sound level Hi 46, Me 40, Lo 34 49
Heating
Power level 62 64
Exterior dimensions
Height × Width × Depth mm 250 × 815 × 247 640 × 850 × 290
Color Cool white Stucco white
Net weight kg 9.0 43
Refrigerant equipment
– 5CS102XFA [Scroll type] × 1
Compressor type & Q’ty
Motor kW – 1.5
Starting method – Line starting
Heat exchanger Slit fins + Louver fins & inner grooved tubing Straight fins & inner grooved tubing
Refrigerant control Capillary tubes + Electronic expansion valve
Refrigerant(3) kg R410A 1.35 (Pre-Charged up to the piping length of 15m)
Refrigerant oil R 0.36 (RB68A)
Deice control Microcomputer control
Air handling equipment
Tangential fan × 1 Propeller fan × 1
Fan type & Q’ty
Motor W 29 45
(Cooling) 11.5 42
Air flow (at High) CMM
(Heating) 13.0 42
Air filter, Q’ty Polypropylene net (washable) × 2 –
Shock & vibration absorber – Cushion rubber (for compressor)
Electric heater – –
Operation control
Wireless-Remote controller –
Operation switch
Room temperature control Microcomputer thermostat –
Pilot lamp RUN (Green), TIMER (Yellow), HI POWER (Green), ECONO (Orange)
Safety equipment Compressor overheat protection, Heating overload protection (High pressure control), Overcurrent protection,
Frost protection, Serial signal error protection, Indoor fan motor error protection, Cooling overload protection
O.D mm (in) Liquid line: φ6.35 (1/4″) Gas line: φ12.7 (1/2″)
nt Connecting method Flare connecting
a
Refrigerpiping AIntstauclahteiodn length of piping LGiqausi dli nlien e: :0 0.4.407 m mNecessary (Both sides) –
Drain hose Connectable
Power source cord 2.5 m (3 cores with Earth)
Size × Core number 1.5 mm2 × 4 cores (Including earth cable)
Connection wiring
Connecting method Terminal block (Screw fixing type)
Accessories (included) Mounting kit
Optional parts –
Notes(1) The data are measured at the following conditions.
Item Indoor air temperature Outdoor air temperature
Standards
Operation DB WB DB WB
Cooling 27ºC 19ºC 35ºC 24ºC ISO-T1, JIS C9612
Heating 20ºC – 7ºC 6ºC ISO-T1, JIS C9612
The piping length is 7.5m.
(2) The operation data are applied to the 220/230/240V districts respectively.
(3) The refrigerant quantity to be charged includes the refrigerant in 15 m connecting piping.
(Purging is not required even for the short piping.)
If the piping length is longer, when it is 15 to 25m, add 20 g refrigerant per meter.
10