Table Of ContentCENTRIMASTER GT-1
DIRECT DRIVEN, SINGLE INLET CENTRIFUGAL FANS
TECHNICAL CATALOGUE
Centrimaster GT-1 - Technical Catalogue 3
CONTENTS
GENERAL DESCRIPTION .....................................................................................4 ACCESSORIES
Versions ...........................................................................................................4 GTLZ-11/GTLZ-12 Flexible connection, inlet ................................. 38
GTLZ-21/GTLZ-22 Flexible connection, outlet ...............................38
GENERAL SURVEY CHARTS ..........................................................................5 GTLZ-24 Counterflange, outlet ........................................................... 38
GTLZ-13/GTLZ-15 Protctive screen, inlet .........................................38
DESIGN DESCRIPTION ........................................................................................6 GTLZ-23/GTLZ-18 Protective screen, outlet ...................................39
GTLZ-32 Inspection cover .....................................................................39
MATERIALS AND FINISH ....................................................................................7
GTLZ-34 Drain .............................................................................................39
MOTOR .......................................................................................................................7
GTLZ-42 Anti vibration mountings, rubber ......................................39
QUALITY & ENVIRONMENT ................................................................................7
GTLZ-50/GTLZ-51 Flow measuring device ....................................39
TOLERANCES ..........................................................................................................7
GTLZ-60 Painted finish ...........................................................................39
GTLZ-77 Motor protection.......................................................................39
FAN CHART EXPLANATION AND DEFINITIONS .........................................8
ACOUSTIC DATA EXPLANATIONS .................................................................9
SPECIFICATION TEXT
GTLB-1 ............................................................................................................40
TECHNICAL DATA INCL. DIMENSIONS, MOTOR DATA AND WEIGHTS
GTLF-1 ............................................................................................................40
GTLB-1-022 ..................................................................................................10
High Temperature (GTLB-1) ...................................................................40
GTLB-1-025 ...................................................................................................12
ATEX (GTLB-1) .............................................................................................40
GTLB-1-028 ...................................................................................................14
GTLB-1-031 . ................................................................................................16
GTLB-1-035 ...................................................................................................18 IMPORTANT INFORMATION
ATEX Directive 94/9/EC .........................................................................41
GTLB-1-040 . ................................................................................................20
GTLB-1-045 ..................................................................................................22
ORDERING CODES ..............................................................................................42
GTLB-1-050 ..................................................................................................24
Accessories ................................................................................................43
GTLB-1-056 ..................................................................................................26
GTLB-1-063 ..................................................................................................28
GTLB-1-071 ...................................................................................................30
GTLF-1-020 ..................................................................................................32
GTLF-1-022 ...................................................................................................34
GTLF-1-025 .................................................................................................36
FläktGroup DC_9993GB_20180629_R0 Specifications are subject to alteration without notice
4 Centrimaster GT-1 - Technical Catalogue
GENERAL DESCRIPTION
The CentriMaster GTLB-1 and GTLF-1 are direct driven, single inlet
centrifugal fans. The range covers air flows up to 9 m3/s (32 400
m3/h) and pressure rises up to 3 000 Pa with GTLB-1 and up to
1.1 m3/s (3 960 m3/h) and pressure rises up to 1 600 Pa max
with GTLF-1. The fan series consists of centrifugal fans available
with two types of impeller:
• Impeller with backward curved blades for the GTLB fans
• Impeller with forward curved blades for the GTLF fans
VERSIONS
STANDARD VERSION
The GTLB-1 and GTLF-1 fans are rated for continuous operation
at temperatures up to +80° C if the inlet of the fan is connected
to the ducting. If the motor is exposed to the air stream, i.e. on a
free inlet fan, the ambient temperature must not exceed +40° C.
HIGH TEMPERATURE VERSION
The high temperature (HT) version is used for smoke extraction
purposes. It has been tested and certified to withstand 400 °C for
2 hours by SP Technical Research Institute of Sweden, conform-
ing with the standard EN 12101-3.
Only GTLB-1 fans are available as high temperature version.
See specification text on page 40.
ATEX VERSION Backward curved impeller Forward curved impeller
The ATEX version is used in potentially explosive atmospheres
according to Directive 2014/34/EU using Ex de motors.
Only GTLB-1 fans are available as ATEX version.
See specification text on page 40.
FläktGroup DC_9993GB_20180629_R0 Specifications are subject to alteration without notice
Centrimaster GT-1 - Technical Catalogue 5
GENERAL SURVEY CHARTS
GTLB-1
3500
3000
2500
a)
P
e ( 2000
ur
s
s
e
Pr
al
ot 1500
T
1000
071
050 056 063
500
035 040 045
031
022025 028
0
0 5000 10000 15000 20000 25000 30000 35000 (m3/h)40000
0 2 4 6 8 10 (m3/s)
Volume flow rate
GTLF-1
1800
1600
022
1400
1200
020
a)
P
e ( 1000
ur
s
s
e
Pr
al 800
ot
T
600
400
025
200
0
0 1000 2000 3000 (m3/h) 4000
0 0.2 0.4 0.6 0.8 1.0 (m3/s)
Volume flow rate
FläktGroup DC_9993GB_20180629_R0 Specifications are subject to alteration without notice
6 Centrimaster GT-1 - Technical Catalogue
DESIGN DESCRIPTION
FAN CASING FAN IMPELLERS
The fan casing is made of Sendzimir galvanized sheet steel. The The fan impellers with backward curved blades (GTLB) are made
casing side plates are deep drawn. Inlet cone for GTLF-1 is a part of welded sheet steel and coated with 60 μm thick epoxy powder
of the side plate of the casing whereas the GTLB-1 fans have a (colour RAL 6029 green).
separate inlet cone. The fan casing is jointed using Pittsburg fold- The fan impellers with forward curved blades (GTLF) are made of
ing method, which produces tight and strong joints. This jointing Sendzimir galvanized sheet steel.
method and the deep drawn inlet cone guarantee a stable design
and high quality. The cut-off is designed to offer optimized aero-
dynamic properties.
Fan impeller of the type GTLB fans Fan impeller of the type GTLF fans
FAN INLET
The fan inlet of a GTLB-1 fan is specially designed to ensure high
fan efficiency and low sound level generated by the fan. The inlet
cone is deep drawn in one piece and fastened to the side plate of
the fan casing.
Inlet cone of the GTLF-1 fans is deep drawn in the fan casing.
MOTOR BRACKET
The ATEX version of GTLB-1 has an inlet cone made of copper.
The motor bracket is made of Sendzimir galvanized sheet steel
and fastened directly to the fan casing.
FläktGroup DC_9993GB_20180629_R0 Specifications are subject to alteration without notice
Centrimaster GT-1 - Technical Catalogue 7
MATERIAL AND FINISH, MOTOR, QUALITY & ENVIRONMENT, TOLERANCES
MATERIAL AND FINISH ErP DIRECTIVE RELATED DATA
The GT fans meet the environmental class C2 as standard. 250 μm All the product related data is available in the software. The fans
painting gives a painting class C5. are ErP 2015 compliant.
Fan casing: Sendzimir galvanized sheet steel
TOLERANCES
Inlet cone: Sendzimir galvanized sheet steel in standard
version, copper in the ATEX version The particulars in the charts are given with the tolerance speci-
fied in the DIN 24 166 Standard, Class 2 for complete fan.
Impeller: GTLB: Welded sheet steel and coated with epoxy
powder 60 μm Tolerance class
DIN 24 166
1 2 3
GTLF: Sendzimir galvanized steel
Air flow q ±2,5 % ±5 % ±10 %
v
Pressure rise, Δp ±2,5 % ±5 % ±10 %
MOTOR f
Shaft power1), Pr +3 % +5 % +16 %
The motor used in standard and high temperatur (HT) version
Efficiency2), ηf –2 % –5 % –
is an IEC standard IE3 motor. It is equipped with thermistor as
A-weighted sound
standard. Motors are designed to be used with a frequency power level1), L +3 dB +4 dB +6 dB
WA
converter. Degree of protection for the standard motors is IP 54.
1) Negative tolerance permissible
See specification text on page 40.
2) Positive tolerance permissible
Motors in ATEX-version are flameproof Ex de IIB T4 motors
equipped with a surface temperature sensor and can be driven
with a speed controller.
See specification text on page 40.
QUALITY & ENVIRONMENT
All components are designed and manufactured in accordance
with applicable standards including the quality assurance system
ISO 9001, the environmental management system ISO 14001 and
the Energy Directive 2009/125/EC and all directives related to
CE-marking.
FläktGroup DC_9993GB_20180629_R0 Specifications are subject to alteration without notice
8 Centrimaster GT-1 - Technical Catalogue
FAN AND POWER DEMAND CHART EXPLANATIONS, DEFINITIONS
FAN CHART EXPLANATIONS SYMBOLS USED
❶
q m3/h The fan charts presented on the following pages are applicable to
v
0 1000 2000 3000 4000 5000 air with a density of 1.2 kg/m³.
2800
2600 4500 r/min-3 kW ❸ 75 ❶
78 ❹ qv Volume flow rate m3/s, m3/h
2400 4240-2,2 79% ❷ Δp Total pressure rise Pa
f
2200
4000-ATEX max 78 ❸
Fan max speed curve and motor
2000
3740-1,5 75 nominal power with different motors
1800
❷ using VSD or synchronous speed
Pa)1600 3370-1,1 70 without VSD.
p (f1400 Red line, max speed for
∆
1200 2970-0,75 87 60 ATEX and HT version r/min, kW
1000 2825-2 pole ❹ η Fan total efficiency %
800 2520-0,55 84 ❺ 50 ❺
2340-0,37 81 LwA Total A-weighted sound power level
600 2050-0,25 90 dB(A) at the discharge side dB(A)
93
400
96
200
3000-HT max
0
0 0,2 0,4 0,6❶ 0,8 1,0 1,2 1,4 1,6
q m3/s
v
FläktGroup DC_9993GB_20180629_R0 Specifications are subject to alteration without notice
Centrimaster GT-1 - Technical Catalogue 9
ACOUSTIC DATA EXPLANATIONS
The total A-weighted sound power level LWA on the outlet side SYMBOLS USED
of a fan with ducted inlet and outlet is specified in the fan chart.
L A-weighted sound power level emitted to
WA
Sound power levels at different octave bands and different sound
the outlet duct, specified in the fan chart dB(A)
paths can be calculated using the following formula:
L A-weighted sound power level
WA(s)
equivalent to sound path s dB(A)
L = L + K
Woct(s) WA oct(s)
L Total sound power level at each octave
Woct(s)
where K values can be obtained from the table. The following band (without A-weighting, corresponding
oct
formula can be used for calculating the A-weighted sound power to sound path s) dB
level on each sound path: L Total sound power level (without A-weighting,
Wt(s)
corresponding to sound path s) dB
L = L + ΔL
WA(s) WA WA(s) K Correction figure for breaking down the
oct(s)
sound level at each octave (corresponding
where the correction figure ΔL can be obtained from the
WA(s) to sound path s) dB
table. The table also includes correction figures ΔL that can
Wt(s) s Sound path
be used for obtaining the total sound power level on each sound
L Distance m
path:
L = L + ΔL ΔL Distance absorption (applicable to ideal
Wt(s) WA(s) Wt(s)
conditions with hemispherical sound propagation) dB
SOUND PATHS L A-weighted sound pressure level at
pA(s)
Sound paths used in the acoustic data tables distance L from fan (corresponding to
sound path s) dB(A)
Sound path
DISTANCE ABSORPTION
To outlet duct
The following formula is used to obtain the sound pressure level
LpA(s) on free sound emission to the surroundings (sound paths
3 and 4) at various distances L:
To inlet duct
L = L – ΔL
pA(s) WA(s)
Through the casing where the distance absorption ΔL can be obtained from the table
below:
L, m 1 3 5 10 15 20 25 30 40 50 75 100
ΔL, dB 8 17 22 28 31 34 36 37 40 42 45 48
To fan outlet (for open discharge fan)
SOUND DATA EXAMPLE - GTLB-1-028
Sound path s Min r/min Max r/min Correction (dB) Koct in octave band mid frequency (Hz) LWA(s) – LWA LWt(s) – LWA(s)
63 125 250 500 1000 2000 4000 8000 dB dB
0 1928 1 2 3 –4 –7 –8 –13 –16 0 7.6
To outlet duct 1928 3857 –1 –1 –7 –1 –6 –8 –12 –16 0 4.9
3857 4500 –4 –3 –2 –8 –4 –7 –10 –14 0 3.9
0 1928 1 1 3 –2 –5 –10 –12 –17 0.6 6.9
To inlet duct 1928 3857 –2 –2 –8 0 –4 –10 –11 –17 0.7 4.1
3857 4500 –4 –3 –4 –5 –2 –9 –11 –16 0.5 3.4
0 1928 –7 –5 –4 –9 –12 –14 –21 –31 –6.1 6.7
Through the casing 1928 3857 –9 –8 –10 –8 –12 –15 –23 –35 –6.9 5.0
3857 4500 –13 –12 –8 –14 –8 –15 –21 –33 –6.0 3.1
0 1928 –14 –5 0 –5 –7 –8 –13 –16 –1.1 4.3
To fan outlet (for
1928 3857 –20 –9 –10 –2 –6 –8 –12 –16 –0.5 1.9
open discharge fan)
3857 4500 –24 –12 –5 –9 –4 –7 –10 –14 –0.4 1.4
For information how to calculate sound data, sound pressure level and distance absorption, see page 9.
FläktGroup DC_9993GB_20180629_R0 Specifications are subject to alteration without notice
10 Centrimaster GT-1 - Technical Catalogue
GTLB-1-022 - FAN CHARTS, MOTOR DATA
DIRECT DRIVEN, SINGLE-INLET, BACKWARD-CURVED BLADES
Impeller diameter: 220 mm
q m3/h
v
0 500 1000 1500 2000 2500 3000
2200
2000 70
5000 r/min-1,1 kW
75
1800
78%
1600 4500-0,75
1400
75
4060-0,55
p (Pa)f1200 70
∆
1000 3560-0,37
84
800 60
81
600 2730-2 pole 50
78
2500-0,25 87 dB(A)
400
90
93
200 ATEX: Max speed is 4000 r/min
4000-ATEX max HT: Not available for size 022
0
0 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9
q m3/s
v
SOUND DATA
Sound path s Min r/min Max r/min Correction (dB) Koct in octave band mid frequency (Hz) LWA(s) – LWA LWt(s) – LWA(s)
63 125 250 500 1000 2000 4000 8000 dB dB
0 1928 2 2 3 –4 –6 –9 –12 –16 0 7.8
To outlet duct 1928 3857 2 –1 –5 –1 –6 –8 –12 –16 0 5.9
3857 5000 –3 –3 –2 –6 –4 –8 –10 –14 0 4.2
0 1928 4 1 2 –4 –6 –9 –12 –16 –0.2 8.1
To inlet duct 1928 3857 1 –2 –6 0 –4 –9 –11 –16 0.9 4.9
3857 5000 –2 –4 –4 –6 –2 –9 –11 –16 0.4 3.6
0 1928 –6 –5 –3 –9 –11 –15 –20 –31 –5.7 6.9
Through the casing 1928 3857 –6 –8 –9 –7 –12 –15 –23 –35 –6.4 5.6
3857 5000 –12 –13 –8 –12 –8 –15 –21 –33 –5.8 3.1
0 1928 –15 –7 –2 –6 –6 –9 –12 –16 –1.4 3.4
To fan outlet 1928 3857 –19 –11 –10 –3 –6 –8 –12 –16 –0.9 1.7
3857 5000 –26 –14 –7 –8 –4 –8 –10 –14 –0.7 1.1
For information how to calculate sound data, sound pressure level and remote attenuation, see page 9.
MOTOR DATA ATEX VERSION
Nom Nom Nom Max Motor Total1)
Motor Number Max Anti vibration Front Back
Motor Code Power Speed current speed weight weight Hub Code
IEC of Poles Hz mounting code ØA H5 * ØA H5 *
kW r/min A r/min kg kg
AXDE-2-00075-c-2-0 80 2 0,75 2877 1,5 4000 69,5 28 39 HULB-1-022-d8-19-1 GTLZ-44-1-022-1-0 30 36 A 30 36 A
1) Appr. total weight in kg for motor and fan (casing + impeller).
FläktGroup DC_9993GB_20180629_R0 Specifications are subject to alteration without notice
Description:28. 39. HULB-1-022-d8-19-1 GTLZ-44-1-022-1-0 30 36 A 30 36 A. 1) Appr. total weight in kg for motor and fan (casing + impeller). GTLB-1-022 - FAN